Schneider Electric

Schneider Electric PJL36025U33A Circuit breaker, PowerPacT P, 250A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0, 80%

(No reviews yet) Write a Review
SKU:
PJL36025U33A
MPN:
PJL36025U33A
Condition:
New
Trip Unit Name:
MicroLogic 5.0
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Country of Origin:
Mexico
Mounting Mode:
unit mount lug)
Product Or Component Type:
circuit breaker
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Poles Description:
3P
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Depth:
8.05 in
Line Rated Current:
250-250 A
Product Name:
PowerPact P
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green)
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Device Application:
distribution
Range:
PowerPact
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
J
Circuit Breaker Application:
HACR rated
Quantity Per Set:
1
Weight:
32 lb(US)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Circularity Profile:
ENVEOLI2206033EN
Network Frequency:
50/60 Hz
Mounting Support:
lug
Ambient Air Temperature For Operation:
-25-70°C
Quality Labels:
CE
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Pollution Degree:
3 IEC 60947-1
Terminal Identifier:
AL800M23K
Electrical Connection:
lugs, line || lugs, load
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Continuous Current Rating:
0.8
Ambient Air Temperature For Storage:
-50-85°C
Wire Stripping Length:
25 mm
Environmental Disclosure:
ENVPEP2206033EN
Warranty:
18 months
Eu Rohs Directive:
Compliant with Exemptions
Mercury Free:
Yes
$15,909.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 250A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose