Schneider Electric

Schneider Electric PJL36040CU33A Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0, 100%

(No reviews yet) Write a Review
SKU:
PJL36040CU33A
MPN:
PJL36040CU33A
Condition:
New
Wire Stripping Length:
25 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Name:
MicroLogic 5.0
Mercury Free:
Yes
Line Rated Current:
400-400 A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Mounting Mode:
unit mount lug)
Range:
PowerPact
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Pvc Free:
Yes
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Weight:
32 lb(US)
Ambient Air Temperature For Storage:
-50-85°C
Circularity Profile:
ENVEOLI2206033EN
Poles Description:
3P
Length:
25 mm
Quantity Per Set:
1
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Circuit Breaker Application:
HACR rated
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Breaking Capacity Code:
J
Product Name:
PowerPact P
Quality Labels:
CE
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Rohs Exemption Information:
Yes
Terminal Identifier:
AL800M23K
Continuous Current Rating:
1
Mounting Support:
lug
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Control Type:
toggle
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
front cover IP40
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP2206033EN
Pollution Degree:
3 IEC 60947-1
Net Weight:
32 lb(US)
Electrical Connection:
lugs, line || lugs, load
Ambient Air Temperature For Operation:
-25-70°C
Depth:
8.05 in
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Warranty:
18 months
$23,187.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose