Schneider Electric

Schneider Electric PJL36040CU41A Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 100%

(No reviews yet) Write a Review
SKU:
PJL36040CU41A
MPN:
PJL36040CU41A
Condition:
New
Continuous Current Rating:
1
Depth:
8.05 in
Device Application:
distribution
Height:
12.86 in
Product Or Component Type:
circuit breaker
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Line Rated Current:
400-400 A
Terminal Identifier:
AL800M23K
Electrical Connection:
lugs, line || lugs, load
Wire Stripping Length:
25 mm
Country of Origin:
United States
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Mounting Support:
lug
Ambient Air Temperature For Operation:
-25-70°C
Trip Unit Technology:
electronic, ammeter, MicroLogic 3.0 A, LI
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Range:
PowerPact
Length:
25 mm
Circularity Profile:
ENVEOLI2206033EN
Product Name:
PowerPact P
Quality Labels:
CE
Ip Degree Of Protection:
front cover IP40
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Quantity Per Set:
1
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Ambient Air Temperature For Storage:
-50-85°C
Poles Description:
3P
Warranty:
18 months
Pvc Free:
Yes
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Environmental Disclosure:
ENVPEP2206033EN
Network Frequency:
50/60 Hz
Rohs Exemption Information:
Yes
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Mercury Free:
Yes
Trip Unit Name:
MicroLogic 3.0 A
Circuit Breaker Application:
HACR rated
Net Weight:
32 lb(US)
$23,670.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 3.0A trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose