Schneider Electric

Schneider Electric PJL36040U64AE1 Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 25kA, lugs, Micrologic 6.0P, 80%, modbus

(No reviews yet) Write a Review
SKU:
PJL36040U64AE1
MPN:
PJL36040U64AE1
Condition:
New
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Pollution Degree:
3 IEC 60947-1
Ip Degree Of Protection:
front cover IP40
Terminal Identifier:
AL800M23K
Quality Labels:
CE
Range:
PowerPact
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Or Component Type:
circuit breaker
Net Weight:
32 lb(US)
Line Rated Current:
400-400 A
Trip Unit Technology:
electronic, power, MicroLogic 6.0 P, LSI
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
Mercury Free:
Yes
Accessory / Separate Part Type:
Modbus connecting cable
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Device Application:
distribution
Sustainable Offer Status:
Green Premium product
Circularity Profile:
ENVEOLI2206033EN
Mounting Mode:
unit mount lug)
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Environmental Disclosure:
ENVPEP2206033EN
Quantity Per Set:
1
Weight:
32 lb(US)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Trip Unit Name:
MicroLogic 6.0 P
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Product Certifications:
UL || CSA || NOM
Country of Origin:
Italy
Poles Description:
3P
Length:
25 mm
Pvc Free:
Yes
Mounting Support:
lug
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Wire Stripping Length:
25 mm
Breaking Capacity Code:
J
Ambient Air Temperature For Storage:
-50-85°C
Ambient Air Temperature For Operation:
-25-70°C
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Electrical Connection:
lugs, line || lugs, load
Product Name:
PowerPact P
Width:
8.27 in
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
$23,414.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 6.0P trip unit and an LSIG function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose