Schneider Electric

Schneider Electric PJL36060CU41A Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 3.0A, 100%

(No reviews yet) Write a Review
SKU:
PJL36060CU41A
MPN:
PJL36060CU41A
Condition:
New
Control Type:
toggle
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Depth:
8.05 in
Network Frequency:
50/60 Hz
Product Or Component Type:
circuit breaker
Environmental Disclosure:
ENVPEP2206033EN
Range:
PowerPact
Weight:
32 lb(US)
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Length:
25 mm
Trip Unit Name:
MicroLogic 3.0 A
Product Name:
PowerPact P
Country of Origin:
United States
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Quality Labels:
CE
Height:
12.86 in
Breaking Capacity Code:
J
Poles Description:
3P
Line Rated Current:
600-600 A
Warranty:
18 months
Mounting Mode:
unit mount lug)
Pvc Free:
Yes
Product Certifications:
UL || CSA || NOM
Device Application:
distribution
Circularity Profile:
ENVEOLI2206033EN
Ambient Air Temperature For Storage:
-50-85°C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Electrical Connection:
lugs, line || lugs, load
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
front cover IP40
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Trip Unit Technology:
electronic, ammeter, MicroLogic 3.0 A, LI
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Sustainable Offer Status:
Green Premium product
Wire Stripping Length:
25 mm
Terminal Identifier:
AL800M23K
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Operation:
-25-70°C
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Quantity Per Set:
1
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
$23,670.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 3.0A trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose