Schneider Electric

Schneider Electric PJL36100U64AE1 Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 6.0P, 80%, modbus

(No reviews yet) Write a Review
SKU:
PJL36100U64AE1
MPN:
PJL36100U64AE1
Condition:
New
Device Application:
distribution
Ambient Air Temperature For Operation:
-25-70°C
Breaking Capacity Code:
J
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Range:
PowerPact
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ip Degree Of Protection:
front cover IP40
Net Weight:
32 lb(US)
Mercury Free:
Yes
Terminal Identifier:
AL1200P25K
Control Type:
toggle
Warranty:
18 months
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Line Rated Current:
1000-1000 A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Length:
30 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Network Frequency:
50/60 Hz
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Wire Stripping Length:
30 mm
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Sustainable Offer Status:
Green Premium product
Quality Labels:
CE
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Technology:
electronic, power, MicroLogic 6.0 P, LSI
Product Or Component Type:
circuit breaker
Weight:
32 lb(US)
Mounting Mode:
unit mount lug)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Continuous Current Rating:
0.8
Product Name:
PowerPact P
Circularity Profile:
ENVEOLI2206033EN
Communication Interface:
Modbus
Trip Unit Name:
MicroLogic 6.0 P
Circuit Breaker Application:
HACR rated
Depth:
8.05 in
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Pollution Degree:
3 IEC 60947-1
Poles Description:
3P
Accessory / Separate Part Type:
Modbus connecting cable
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Mounting Support:
lug
Quantity Per Set:
1
$28,881.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 6.0P trip unit and an LSIG function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose