Schneider Electric

Schneider Electric PJP36100U33A Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0, 80%

(No reviews yet) Write a Review
SKU:
PJP36100U33A
MPN:
PJP36100U33A
Condition:
New
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Net Weight:
32 lb(US)
Device Application:
distribution
Length:
30 mm
Breaking Capacity Code:
J
Local Signaling:
overload 1 1 LED amber) || 1 trip indicator green)
Quality Labels:
CE
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Wire Stripping Length:
30 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
unit mount lug)
Control Type:
toggle
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Product Certifications:
UL || CSA || NOM
Network Frequency:
50/60 Hz
Product Or Component Type:
circuit breaker
Country of Origin:
United States
Mounting Support:
lug
Ip Degree Of Protection:
front cover IP40
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Name:
MicroLogic 5.0
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pollution Degree:
3 IEC 60947-1
Range:
PowerPact
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Circuit Breaker Application:
HACR rated
Circularity Profile:
ENVEOLI2206033EN
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Depth:
8.05 in
Product Name:
PowerPact P
Weight:
32 lb(US)
Continuous Current Rating:
0.8
Eu Rohs Directive:
Compliant with Exemptions
Warranty:
18 months
Terminal Identifier:
AL1200P25K
Rohs Exemption Information:
Yes
Line Rated Current:
1000-1000 A
Electrical Connection:
terminal nut, line || lugs, load
Ambient Air Temperature For Operation:
-25-70°C
$21,378.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has terminal nuts on the line side and lugs on the load side. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.