Schneider Electric

Schneider Electric PKA36040U31A Circuit breaker, PowerPacT P, 400A, 3 pole, 600VAC, 100kA, I-Line, Micrologic 3.0, 100%, ABC

(No reviews yet) Write a Review
SKU:
PKA36040U31A
MPN:
PKA36040U31A
Condition:
New
Weight:
32 lb(US)
Trip Unit Name:
MicroLogic 3.0
Height:
9 in
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Device Application:
distribution
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Support:
bracket
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Mounting Mode:
I-Line bracket)
Pollution Degree:
3 IEC 60947-1
Poles Description:
3P
Circularity Profile:
ENVEOLI2206033EN
Height:
12.86 in
Quantity Per Set:
1
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Quality Labels:
CE
Length:
25 mm
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green)
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Ip Degree Of Protection:
front cover IP40
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Rohs Exemption Information:
Yes
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 50 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Line Rated Current:
400-400 A
Ambient Air Temperature For Operation:
-25-70°C
Mercury Free:
Yes
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Network Frequency:
50/60 Hz
Depth:
8.05 in
Utilisation Category:
category A
Electrical Connection:
I-Line connection, line || lugs, load
Mounting Height:
9 in
Wire Stripping Length:
25 mm
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
Country of Origin:
Mexico
Control Type:
toggle
Terminal Identifier:
AL800M23K
Phase Connection:
ABC
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
32 lb(US)
Environmental Disclosure:
ENVPEP2206033EN
$24,402.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 400A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose