Schneider Electric

Schneider Electric PKA36080U64AE1 Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 100kA, I-Line, Micrologic 6.0P, 80%, ABC, modbus

(No reviews yet) Write a Review
SKU:
PKA36080U64AE1
MPN:
PKA36080U64AE1
Condition:
New
Communication Interface:
Modbus
Environmental Disclosure:
ENVPEP2206033EN
Eu Rohs Directive:
Compliant with Exemptions
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Terminal Identifier:
AL800M23K
Range:
PowerPact
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Length:
25 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Or Component Type:
circuit breaker
Sustainable Offer Status:
Green Premium product
Ambient Air Temperature For Storage:
-50-85°C
Rohs Exemption Information:
Yes
Mounting Height:
9 in
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Wire Stripping Length:
25 mm
Weight:
32 lb(US)
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Breaking Capacity Code:
K
Control Type:
toggle
Continuous Current Rating:
0.8
Mounting Support:
bracket
Net Weight:
32 lb(US)
Circularity Profile:
ENVEOLI2206033EN
Quantity Per Set:
1
Ip Degree Of Protection:
front cover IP40
Quality Labels:
CE
Height:
9 in
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Mounting Mode:
I-Line bracket)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Electrical Connection:
I-Line connection, line || lugs, load
Warranty:
18 months
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Phase Connection:
ABC
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 50 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Product Certifications:
UL || CSA || NOM
Accessory / Separate Part Type:
Modbus connecting cable
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Trip Unit Name:
MicroLogic 6.0 P
Pvc Free:
Yes
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Pollution Degree:
3 IEC 60947-1
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Mercury Free:
Yes
Height:
12.86 in
Line Rated Current:
800-800 A
$24,111.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 6.0P trip unit and an LSIG function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose