Schneider Electric

Schneider Electric PKA36100U44A Circuit breaker, PowerPacT P, 1000A, 3 pole, 600VAC, 100kA, I-Line, Micrologic 6.0A, 80%, ABC

(No reviews yet) Write a Review
SKU:
PKA36100U44A
MPN:
PKA36100U44A
Condition:
New
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Product Name:
PowerPact P
Electrical Connection:
I-Line connection, line || lugs, load
Ip Degree Of Protection:
front cover IP40
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
Weight:
32 lb(US)
Rohs Exemption Information:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Mercury Free:
Yes
Height:
16.16 in
Eu Rohs Directive:
Compliant with Exemptions
Line Rated Current:
1000-1000 A
Mounting Height:
9 in
Sustainable Offer Status:
Green Premium product
Net Weight:
32 lb(US)
Product Or Component Type:
circuit breaker
Length:
30 mm
Continuous Current Rating:
0.8
Quantity Per Set:
1
Control Type:
toggle
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 50 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Country of Origin:
United States
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circuit Breaker Application:
HACR rated
Depth:
8.05 in
Circularity Profile:
ENVEOLI2206033EN
Product Certifications:
UL || CSA || NOM
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Warranty:
18 months
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Device Application:
distribution
Poles Description:
3P
Quality Labels:
CE
Width:
8.27 in
Range:
PowerPact
Mounting Support:
bracket
Network Frequency:
50/60 Hz
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Height:
9 in
Environmental Disclosure:
ENVPEP2206033EN
Mounting Mode:
I-Line bracket)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
$26,211.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose