Schneider Electric

Schneider Electric PKA36120 Circuit breaker, PowerPacT P, 1200A, 3 pole, 600VAC, 100kA, I-Line, ET1.0l, 80%, ABC

(No reviews yet) Write a Review
SKU:
PKA36120
MPN:
PKA36120
Condition:
New
Quantity Per Set:
1
Mounting Mode:
I-Line bracket)
Weight:
32 lb(US)
Utilisation Category:
category A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Breaking Capacity Code:
K
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Warranty:
18 months
Poles Description:
3P
Pvc Free:
Yes
Mounting Support:
bracket
Ambient Air Temperature For Operation:
-25-70°C
Continuous Current Rating:
0.8
Control Type:
toggle
Trip Unit Name:
ET 1.0I
Sustainable Offer Status:
Green Premium product
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Length:
30 mm
Long Time Pick-Up Adjustment Range:
1 In
Environmental Disclosure:
ENVPEP2206033EN
Device Application:
distribution
Phase Connection:
ABC
Electrical Connection:
I-Line connection, line || lugs, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Suitability For Isolation:
yes IEC 60947-2
Network Frequency:
50/60 Hz
Terminal Identifier:
AL1200P25K
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Range:
PowerPact
Depth:
8.05 in
Quality Labels:
CE
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Product Certifications:
UL || CSA || NOM
Height:
16.16 in
Country of Origin:
United States
Net Weight:
32 lb(US)
Wire Stripping Length:
30 mm
Eu Rohs Directive:
Compliant with Exemptions
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 50 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Application:
HACR rated
Product Or Component Type:
circuit breaker
Line Rated Current:
1200-1200 A
Local Signaling:
1 trip indicator green)
Ambient Air Temperature For Storage:
-50-85°C
Pollution Degree:
3 IEC 60947-1
$21,207.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose