Schneider Electric

Schneider Electric PKL36080 Circuit breaker, PowerPacT P, 800A, 3 pole, 600VAC, 65kA, lugs, ET1.0l, 80%

(No reviews yet) Write a Review
SKU:
PKL36080
MPN:
PKL36080
Condition:
New
Wire Stripping Length:
25 mm
Ambient Air Temperature For Operation:
-25-70°C
Depth:
8.05 in
Quantity Per Set:
1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Country of Origin:
United States
Rohs Exemption Information:
Yes
Product Or Component Type:
circuit breaker
Quality Labels:
CE
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Length:
25 mm
Pollution Degree:
3 IEC 60947-1
Trip Unit Technology:
electronic, basic, ET 1.0I, I
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP2206033EN
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Weight:
32 lb(US)
Product Certifications:
UL || CSA || NOM
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206033EN
Net Weight:
32 lb(US)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Terminal Identifier:
AL800M23K
Suitability For Isolation:
yes IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Control Type:
toggle
Circuit Breaker Application:
HACR rated
Electrical Connection:
lugs, line || lugs, load
Height:
12.86 in
Long Time Pick-Up Adjustment Range:
1 In
Mercury Free:
Yes
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Breaking Capacity Code:
K
Range:
PowerPact
Line Rated Current:
800-800 A
Poles Description:
3P
Trip Unit Name:
ET 1.0I
Mounting Support:
lug
Warranty:
18 months
Utilisation Category:
category A
Device Application:
distribution
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 50 kA 480 V AC 50/60 Hz UL 489 || AIR 50 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
$14,783.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has an electronic trip unit, ET 1.0I. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 50kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose