Product Certifications:
UL Listed
Ambient Air Temperature For Operation:
-5°C || 40°C
Net Weight:
2.800 kg
Material:
tin plated aluminium: busbar
Device Composition:
neutral (factory installed)
Warranty:
18 months
Country of Origin:
Mexico
Nema Degree Of Protection:
NEMA 1 indoor enclosure
Electrical Connection:
lugs
Box Number:
13
Product Or Component Type:
Load Center
Surface Finish:
baked enamel Gray
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Weight:
2.800 kg
Cover Type:
flush cover
Enclosure Material:
welded sheet steel
Short-Circuit Current:
65 kA
Depth:
86 mm
Number Of Tandem Circuit Breakers:
0
Reach Free Of Svhc:
Yes
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC || 240 V delta AC
Tightening Torque:
main lugs 35 lb.in, AWG 14...AWG 10, aluminium/copper || main lugs 50 lb.in, AWG 3...AWG 1, aluminium/copper || main lugs 40 lb.in, AWG 8...AWG 4, aluminium/copper || main lugs 35 lb.in, AWG 12...AWG10, aluminium/copper
Range Of Product:
QO
Toxic Heavy Metal Free:
Yes
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Rohs Exemption Information:
Yes
Load Center Type:
Fixed Mains (lugs)
Number Of Spaces:
3
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Number Of Circuits:
3
Line Rated Current:
60 A
Mercury Free:
Yes
Phase:
3 phase 4 wires
Awg Gauge:
AWG 10...AWG 6 copper
Circularity Profile:
N/A
Environmental Disclosure:
ENVPEP2212001
Eu Rohs Directive:
Compliant
$107.00

Description

QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 3 phase load center has 3 spaces and 3 circuits. This system provides 60A main lugs in a NEMA 1 enclosure. It also includes a neutral ground bar, flush cover, and is UL rated.