Schneider Electric

Schneider Electric QO403L60NRB Load center, QO, 3 phase, 3 spaces, 3 circuits, 60A main lugs, NEMA3R, neutral gnd bar

(No reviews yet) Write a Review
SKU:
QO403L60NRB
MPN:
QO403L60NRB
Condition:
New
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Range Of Product:
QO
Tightening Torque:
main lugs 35 lb.in, AWG 14...AWG 10, aluminium/copper || main lugs 50 lb.in, AWG 3...AWG 1, aluminium/copper || main lugs 40 lb.in, AWG 8...AWG 4, aluminium/copper || main lugs 35 lb.in, AWG 12...AWG10, aluminium/copper
Net Weight:
4.200 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Warranty:
18 months
Weight:
4.200 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile:
N/A
Material:
tin plated aluminium: busbar
Enclosure Material:
welded galvannealed steel
Toxic Heavy Metal Free:
Yes
Surface Finish:
baked enamel Gray
Product Or Component Type:
Load Center
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC || 240 V delta AC
Product Certifications:
UL Listed
Eu Rohs Directive:
Compliant
Box Number:
10R
Line Rated Current:
60 A
Mercury Free:
Yes
Number Of Circuits:
3
Nema Degree Of Protection:
NEMA 3R weatherproof enclosure
Country of Origin:
Mexico
Reach Free Of Svhc:
Yes
Depth:
105 mm
Environmental Disclosure:
ENVPEP2212001
Load Center Type:
Fixed Mains (lugs)
Number Of Tandem Circuit Breakers:
0
Phase:
3 phase 4 wires
Electrical Connection:
lugs
Ambient Air Temperature For Operation:
-5°C || 40°C
Awg Gauge:
AWG 10...AWG 6 copper
Cover Type:
surface cover
Number Of Spaces:
3
Sustainable Offer Status:
Green Premium product
Device Composition:
grounding bar (ordered separately)
Rohs Exemption Information:
Yes
Short-Circuit Current:
65 kA
$177.00

Description

QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 3 phase load center has 3 spaces and 3 circuits. This system provides 60A main lugs in a NEMA 3R enclosure. It also includes a neutral ground bar, and is UL rated. QO load center is UL Listed.
View AllClose