Schneider Electric

Schneider Electric QO403L60NS Load center, QO, 3 phase, 3 spaces, 3 circuits, 60A main lugs, NEMA1, neutral gnd bar, surface cover

(No reviews yet) Write a Review
SKU:
QO403L60NS
MPN:
QO403L60NS
Condition:
New
Number Of Spaces:
3
Number Of Circuits:
3
Box Number:
13
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC || 240 V delta AC
Ambient Air Temperature For Operation:
-5°C || 40°C
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant
Circularity Profile:
N/A
Short-Circuit Current:
65 kA
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Electrical Connection:
lugs
Environmental Disclosure:
ENVPEP2212001
Product Certifications:
UL Listed
Rohs Exemption Information:
Yes
Warranty:
18 months
Phase:
3 phase 4 wires
Toxic Heavy Metal Free:
Yes
Line Rated Current:
60 A
Range Of Product:
QO
Tightening Torque:
main lugs 35 lb.in, AWG 14...AWG 10, aluminium/copper || main lugs 50 lb.in, AWG 3...AWG 1, aluminium/copper || main lugs 40 lb.in, AWG 8...AWG 4, aluminium/copper || main lugs 35 lb.in, AWG 12...AWG10, aluminium/copper
Surface Finish:
baked enamel Gray
Reach Free Of Svhc:
Yes
Mercury Free:
Yes
Device Composition:
neutral (factory installed)
Sustainable Offer Status:
Green Premium product
Cover Type:
surface cover
Enclosure Material:
welded sheet steel
Country of Origin:
United States
Awg Gauge:
AWG 10...AWG 6 copper
Nema Degree Of Protection:
NEMA 1 indoor enclosure
Load Center Type:
Fixed Mains (lugs)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Number Of Tandem Circuit Breakers:
0
Product Or Component Type:
Load Center
Material:
tin plated aluminium: busbar
$107.00

Description

QO Load Centers offer premium features by allowing QO breakers, ground fault interrupters, arc fault interrupters, and surge arresters to be installed inside. QO Load Centers are designed for residential and industrial use to protect electrical systems, equipment, and people. They are available in both traditional and plug on neutral configurations. There is 3 types of mains available. There is main circuit breaker, main lugs, and generator panel. Single and three phase options are available. The bus bars are tin plated copper and are shielded. Indoor and outdoors enclosures are an option. QO Load Centers enable the use of a full complement of accessories. This 3 phase load center has 3 spaces and 3 circuits. This system provides 60A main lugs in a NEMA 1 enclosure. It also includes a neutral ground bar, surface cover, and is UL rated.
View AllClose