Schneider Electric

Schneider Electric RGA36100CU44A Circuit breaker, PowerPacT R, 1000A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 6.0A, 100%

(No reviews yet) Write a Review
SKU:
RGA36100CU44A
MPN:
RGA36100CU44A
Condition:
New
Net Weight:
52 lb(US)
Weight:
52 lb(US)
Awg Gauge:
4 x AWG 3/0…600 kcmil aluminium/copper || 4 x AWG 3/0...500 kcmil copper
Local Signaling:
alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
Country of Origin:
United States
Range:
PowerPact
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Breaking Capacity Code:
G
Environmental Disclosure:
ENVPEP2206034EN
Continuous Current Rating:
1
Utilisation Category:
category A
Quantity Per Set:
1
Pollution Degree:
3 IEC 60947-1
Ambient Air Temperature For Storage:
-50-85°C
Poles Description:
3P
Trip Unit Name:
MicroLogic 6.0 A
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Device Application:
distribution
Rohs Exemption Information:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Length:
30 mm
Electrical Connection:
I-Line connection, line || lugs, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Mounting Mode:
I-Line bracket)
Product Certifications:
UL || CSA || NOM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Product Or Component Type:
circuit breaker
Control Type:
operating handle
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Product Name:
PowerPact R
Mercury Free:
Yes
Pvc Free:
Yes
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI2206034EN
Line Rated Current:
1000-1000 A
Eu Rohs Directive:
Compliant with Exemptions
Terminal Identifier:
AL1200R53K
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Suitability For Isolation:
yes IEC 60947-2
Circuit Breaker Application:
HACR rated
Mounting Support:
bracket
Halogen Content Performance:
Halogen free plastic parts product
$38,378.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose