Schneider Electric

Schneider Electric RGA36120CU33A Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0, 100%

(No reviews yet) Write a Review
SKU:
RGA36120CU33A
MPN:
RGA36120CU33A
Condition:
New
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Rohs Exemption Information:
Yes
Country of Origin:
United States
Awg Gauge:
4 x AWG 3/0…600 kcmil aluminium/copper || 4 x AWG 3/0...500 kcmil copper
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pvc Free:
Yes
Net Weight:
52 lb(US)
Pollution Degree:
3 IEC 60947-1
Halogen Content Performance:
Halogen free plastic parts product
Depth:
13.78 in
Product Or Component Type:
circuit breaker
Continuous Current Rating:
1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Tightening Torque:
28-28 N.m 95-240 mm² (4 x AWG 3/0…600 kcmil)
Ambient Air Temperature For Operation:
-25-70°C
Mounting Support:
bracket
Weight:
52 lb(US)
Circularity Profile:
ENVEOLI2206034EN
Ip Degree Of Protection:
IP40
Circuit Breaker Application:
HACR rated
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
distribution
Network Frequency:
50/60 Hz
Wire Stripping Length:
30 mm
Mercury Free:
Yes
Local Signaling:
alarm 1 LED yellow)long-time pick up)
Range:
PowerPact
Quality Labels:
CE
Terminal Identifier:
AL1200R53K
Electrical Connection:
I-Line connection, line || lugs, load
Sustainable Offer Status:
Green Premium product
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Name:
MicroLogic 5.0
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206034EN
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Ambient Air Temperature For Storage:
-50-85°C
Warranty:
18 months
Quantity Per Set:
1
Control Type:
operating handle
Breaking Capacity Code:
G
$34,401.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose