Schneider Electric RGA36120CU33A Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 5.0, 100%
Schneider Electric
$34,401.00
PowerPacTÂ R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Product Certifications:
- UL || CSA || NOM
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Rohs Exemption Information:
- Yes
- Country of Origin:
- United States
- Awg Gauge:
- 4 x AWG 3/0…600 kcmil aluminium/copper || 4 x AWG 3/0...500 kcmil copper
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Pvc Free:
- Yes
- Net Weight:
- 52 lb(US)
- Pollution Degree:
- 3 IEC 60947-1
- Halogen Content Performance:
- Halogen free plastic parts product
- Depth:
- 13.78 in
- Product Or Component Type:
- circuit breaker
- Continuous Current Rating:
- 1
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Tightening Torque:
- 28-28 N.m 95-240 mm² (4 x AWG 3/0…600 kcmil)
- Ambient Air Temperature For Operation:
- -25-70°C
- Mounting Support:
- bracket
- Weight:
- 52 lb(US)
- Circularity Profile:
- ENVEOLI2206034EN
- Ip Degree Of Protection:
- IP40
- Circuit Breaker Application:
- HACR rated
- Eu Rohs Directive:
- Compliant with Exemptions
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Device Application:
- distribution
- Network Frequency:
- 50/60 Hz
- Wire Stripping Length:
- 30 mm
- Mercury Free:
- Yes
- Local Signaling:
- alarm 1 LED yellow)long-time pick up)
- Range:
- PowerPact
- Quality Labels:
- CE
- Terminal Identifier:
- AL1200R53K
- Electrical Connection:
- I-Line connection, line || lugs, load
- Sustainable Offer Status:
- Green Premium product
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Trip Unit Name:
- MicroLogic 5.0
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Environmental Disclosure:
- ENVPEP2206034EN
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Standards:
- UL || CSA || NEMA || NMX J-266 || IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85°C
- Warranty:
- 18 months
- Quantity Per Set:
- 1
- Control Type:
- operating handle
- Breaking Capacity Code:
- G