Schneider Electric

Schneider Electric RGF36060CU33A Circuit breaker, PowerPacT R, 600A, 3 pole, 600VAC, 18kA, busbar, Micrologic 5.0, 100%

(No reviews yet) Write a Review
SKU:
RGF36060CU33A
MPN:
RGF36060CU33A
Condition:
New
Quality Labels:
CE
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
distribution
Halogen Content Performance:
Halogen free plastic parts product
Quantity Per Set:
1
Country of Origin:
United States
Local Signaling:
alarm 1 LED yellow)long-time pick up)
Utilisation Category:
category A
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Trip Unit Name:
MicroLogic 5.0
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mounting Support:
busbar
Tightening Torque:
62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
Circuit Breaker Application:
HACR rated
Ip Degree Of Protection:
IP40
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Breaking Capacity Code:
G
Product Certifications:
UL || CSA || NOM
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3 IEC 60947-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weight:
52 lb(US)
Product Name:
PowerPact R
Continuous Current Rating:
1
Network Frequency:
50/60 Hz
Environmental Disclosure:
ENVPEP2206034EN
Ambient Air Temperature For Operation:
-25-70°C
Mounting Mode:
unit mount busbar)
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Suitability For Isolation:
yes IEC 60947-2
Net Weight:
52 lb(US)
Line Rated Current:
600-600 A
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
ENVEOLI2206034EN
Control Type:
operating handle
Depth:
14.49 in
Poles Description:
3P
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Terminal Identifier:
AL2500RK
Range:
PowerPact
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Electrical Connection:
busbar connection, line || busbar connection, load
$28,065.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.