Schneider Electric RGF36080U31A Circuit breaker, PowerPacT R, 800A, 3 pole, 600VAC, 18kA, busbar, Micrologic 3.0, 80%
Schneider Electric
$34,740.00
PowerPacTÂ R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Depth:
- 14.49 in
- Weight:
- 52 lb(US)
- Wire Stripping Length:
- 35 mm
- Range:
- PowerPact
- Suitability For Isolation:
- yes IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Ip Degree Of Protection:
- IP40
- Mounting Support:
- busbar
- Product Certifications:
- UL || CSA || NOM
- Pollution Degree:
- 3 IEC 60947-1
- Device Application:
- distribution
- Eu Rohs Directive:
- Compliant
- Rohs Exemption Information:
- Yes
- Control Type:
- operating handle
- Length:
- 35 mm
- Net Weight:
- 52 lb(US)
- Mounting Mode:
- unit mount busbar)
- Ambient Air Temperature For Storage:
- -50-85°C
- Network Frequency:
- 50/60 Hz
- Circularity Profile:
- ENVEOLI1407013EN
- Pvc Free:
- Yes
- Warranty:
- 18 months
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Quantity Per Set:
- 1
- Electrical Connection:
- busbar connection, line || busbar connection, load
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Utilisation Category:
- category A
- Line Rated Current:
- 800-800 A
- Awg Gauge:
- AWG 3/0...750 kcmil aluminium/copper
- Terminal Identifier:
- AL2500RK
- Poles Description:
- 3P
- Height:
- 16.24 in
- Sustainable Offer Status:
- Green Premium product
- Ambient Air Temperature For Operation:
- -25-70°C
- Tightening Torque:
- 62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Halogen Content Performance:
- Halogen free plastic parts product
- Standards:
- UL || CSA || NEMA || NMX J-266 || IEC 60947-2
- Product Name:
- PowerPact R
- Breaking Capacity Code:
- G
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Mercury Free:
- Yes
- Circuit Breaker Application:
- HACR rated
- Country of Origin:
- United States
- Environmental Disclosure:
- ENVPEP1407013EN
- Local Signaling:
- alarm 1 LED yellow)long-time pick up)
- Product Or Component Type:
- circuit breaker
- Trip Unit Name:
- MicroLogic 3.0