Schneider Electric

Schneider Electric RGF36120CU44A Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 18kA, busbar, Micrologic 6.0A, 100%

(No reviews yet) Write a Review
SKU:
RGF36120CU44A
MPN:
RGF36120CU44A
Condition:
New
Net Weight:
52 lb(US)
Ip Degree Of Protection:
IP40
Circularity Profile:
ENVEOLI2206034EN
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
Line Rated Current:
1200-1200 A
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Name:
MicroLogic 6.0 A
Device Application:
distribution
Tightening Torque:
62-62 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 62-62 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weight:
52 lb(US)
Mounting Support:
busbar
Environmental Disclosure:
ENVPEP2206034EN
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Electrical Connection:
busbar connection, line || busbar connection, load
Ambient Air Temperature For Storage:
-50-85°C
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Wire Stripping Length:
35 mm
Pollution Degree:
3 IEC 60947-1
Mercury Free:
Yes
Mounting Mode:
unit mount busbar)
Depth:
14.49 in
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Continuous Current Rating:
1
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Breaking Capacity Code:
G
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
circuit breaker
Suitability For Isolation:
yes IEC 60947-2
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Product Certifications:
UL || CSA || NOM
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Country of Origin:
Mexico
Local Signaling:
alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
Network Frequency:
50/60 Hz
Ambient Air Temperature For Operation:
-25-70°C
Range:
PowerPact
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Circuit Breaker Application:
HACR rated
Terminal Identifier:
AL2500RK
Utilisation Category:
category A
Halogen Content Performance:
Halogen free plastic parts product
$31,556.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.