Schneider Electric

Schneider Electric RGF36200U64AE1 Circuit breaker, PowerPacT R, 2000A, 3 pole, 600VAC, 18kA, busbar, Micrologic 6.0P, 80%, modbus

(No reviews yet) Write a Review
SKU:
RGF36200U64AE1
MPN:
RGF36200U64AE1
Condition:
New
Trip Unit Technology:
electronic, power, MicroLogic 6.0 P, LSIG
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
Mercury Free:
Yes
Quantity Per Set:
1
Mounting Mode:
unit mount busbar)
Trip Unit Name:
MicroLogic 6.0 P
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Circuit Breaker Application:
HACR rated
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Range:
PowerPact
Suitability For Isolation:
yes IEC 60947-2
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Local Signaling:
alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Line Rated Current:
2000-2000 A
Ip Degree Of Protection:
IP40
Wire Stripping Length:
35 mm
Network Frequency:
50/60 Hz
Continuous Current Rating:
0.8
Ambient Air Temperature For Operation:
-25-70°C
Depth:
14.49 in
Quality Labels:
CE
Country of Origin:
United States
Communication Interface:
Modbus
Terminal Identifier:
AL2500RK
Environmental Disclosure:
ENVPEP1407013EN
Pollution Degree:
3 IEC 60947-1
Breaking Capacity Code:
G
Width:
16.53 in
Mounting Support:
busbar
Electrical Connection:
busbar connection, line || busbar connection, load
Length:
35 mm
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact R
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
ENVEOLI1407013EN
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Control Type:
operating handle
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Utilisation Category:
category A
Device Application:
distribution
Net Weight:
52 lb(US)
Ambient Air Temperature For Storage:
-50-85°C
Warranty:
18 months
Halogen Content Performance:
Halogen free plastic parts product
$31,004.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power Trip with a 6.0P trip unit and an LSIG function with Modbus communication. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 2000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose