Schneider Electric RJA36120CU43A Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 25kA, I-Line, Micrologic 5.0A, 100%

(No reviews yet) Write a Review
SKU:
RJA36120CU43A
MPN:
RJA36120CU43A
Condition:
New
Continuous Current Rating:
1
Sustainable Offer Status:
Green Premium product
Terminal Identifier:
AL1200R53K
Net Weight:
52 lb(US)
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Breaking Capacity Code:
J
Rohs Exemption Information:
Yes
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Depth:
13.78 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Tightening Torque:
28-28 N.m 95-240 mm² (4 x AWG 3/0…600 kcmil)
Line Rated Current:
1200-1200 A
Network Frequency:
50/60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Storage:
-50-85°C
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Length:
30 mm
Wire Stripping Length:
30 mm
Country of Origin:
United States
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Mounting Mode:
I-Line bracket)
Suitability For Isolation:
yes IEC 60947-2
Product Name:
PowerPact R
Mounting Support:
bracket
Utilisation Category:
category A
Local Signaling:
alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || phase-loading LED green)load balancing)
Eu Rohs Directive:
Compliant with Exemptions
Control Type:
operating handle
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Circuit Breaker Application:
HACR rated
Range:
PowerPact
Mercury Free:
Yes
Awg Gauge:
4 x AWG 3/0…600 kcmil aluminium/copper || 4 x AWG 3/0...500 kcmil copper
Halogen Content Performance:
Halogen free plastic parts product
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Operation:
-25-70°C
Pvc Free:
Yes
Quality Labels:
CE
Electrical Connection:
I-Line connection, line || lugs, load
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Trip Unit Technology:
electronic, ammeter, MicroLogic 5.0 A, LSI
Trip Unit Name:
MicroLogic 5.0 A
Poles Description:
3P
Circularity Profile:
ENVEOLI2206034EN
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || CSA || NOM
$38,916.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 5.0A trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.