Schneider Electric

Schneider Electric RKA36120CU33A Circuit breaker, PowerPacT R, 1200A, 3 pole, 600VAC, 65kA, I-Line, Micrologic 5.0, 100%

(No reviews yet) Write a Review
SKU:
RKA36120CU33A
MPN:
RKA36120CU33A
Condition:
New
Mounting Mode:
I-Line bracket)
Warranty:
18 months
Breaking Capacity Code:
K
Weight:
52 lb(US)
Local Signaling:
alarm 1 LED yellow)long-time pick up)
Tightening Torque:
28-28 N.m 95-240 mm² (4 x AWG 3/0…600 kcmil)
Device Application:
distribution
Poles Description:
3P
Country of Origin:
United States
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 65 kA 600 V AC 50/60 Hz UL 489 || Icu 85 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 70 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Halogen Content Performance:
Halogen free plastic parts product
Wire Stripping Length:
30 mm
Control Type:
operating handle
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 55 kA 380/415 V AC 50/60 Hz IEC 60947-2
Line Rated Current:
1200-1200 A
Electrical Connection:
I-Line connection, line || lugs, load
Length:
30 mm
Network Frequency:
50/60 Hz
Product Name:
PowerPact R
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Pvc Free:
Yes
Quality Labels:
CE
Width:
14.96 in
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Ip Degree Of Protection:
IP40
Product Or Component Type:
circuit breaker
Terminal Identifier:
AL1200R53K
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Product Certifications:
UL || CSA || NOM
Continuous Current Rating:
1
Suitability For Isolation:
yes IEC 60947-2
Mounting Support:
bracket
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Depth:
13.78 in
Environmental Disclosure:
ENVPEP2206034EN
Range:
PowerPact
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Operation:
-25-70°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Circularity Profile:
ENVEOLI2206034EN
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Circuit Breaker Application:
HACR rated
Eu Rohs Directive:
Compliant with Exemptions
Awg Gauge:
4 x AWG 3/0…600 kcmil aluminium/copper || 4 x AWG 3/0...500 kcmil copper
$36,599.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 65kA at 600VAC. This circuit breaker has a continuous current rating of 100% with an ABC phase connection. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose