Trip Unit Name:
MicroLogic 6.0 P
Poles Description:
3P
Electrical Connection:
busbar connection, line || busbar connection, load
Suitability For Isolation:
yes IEC 60947-2
Pvc Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Circularity Profile:
ENVEOLI2206034EN
Circuit Breaker Application:
HACR rated
Net Weight:
52 lb(US)
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Breaking Capacity Code:
K
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
Product Or Component Type:
circuit breaker
Ambient Air Temperature For Operation:
-25-70°C
Continuous Current Rating:
0.8
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Depth:
14.49 in
Local Signaling:
alarm 1 LED yellow)long-time pick up) || 1 LED red)long-time pick up) || trip causes 1 LED red) || 1 LED red)digital ammeter) || ground indicator 1 LED red) || phase-loading LED green)load balancing)
Weight:
52 lb(US)
Trip Unit Technology:
electronic, power, MicroLogic 6.0 P, LSIG
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Device Application:
distribution
Halogen Content Performance:
Halogen free plastic parts product
Length:
35 mm
Utilisation Category:
category A
Network Frequency:
50/60 Hz
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Environmental Disclosure:
ENVPEP2206034EN
Mounting Mode:
unit mount busbar)
Warranty:
18 months
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 65 kA 600 V AC 50/60 Hz UL 489 || Icu 85 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 70 kA 380/415 V AC 50/60 Hz IEC 60947-2
Pollution Degree:
3 IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
operating handle
Communication Interface:
Modbus
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ics] Rated Service Breaking Capacity:
65 kA 240 V AC 50/60 Hz IEC 60947-2 || 55 kA 380/415 V AC 50/60 Hz IEC 60947-2
Line Rated Current:
2500-2500 A
Width:
16.53 in
Wire Stripping Length:
35 mm
Ambient Air Temperature For Storage:
-50-85°C
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
Mercury Free:
Yes
$46,143.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power Trip with a 6.0P trip unit and an LSIG function with Modbus communication. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 2500A, 3 pole, circuit breaker has an interrupting rating of 65kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.