Schneider Electric

Schneider Electric TM262L01MDESE8T distributed PAC controller, Modicon M262

(No reviews yet) Write a Review
SKU:
TM262L01MDESE8T
MPN:
TM262L01MDESE8T
Condition:
New
Resistance To Electromagnetic Fields:
10 V/m 80 MHz...1 GHz EN/IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz EN/IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz EN/IEC 61000-4-3
Backup Time:
1000 h 25°C
Pollution Degree:
2
Maximum Cable Distance Between Devices:
shielded cable <30 m RS485 link || shielded cable <15 m RS232
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Operating Altitude:
0...6561.68 ft (0...2000 m)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Resistance To Fast Transients:
2 kV EN/IEC 61000-4-4 power lines) || 1 kV EN/IEC 61000-4-4 Ethernet line) || 1 kV EN/IEC 61000-4-4 serial link) || 1 kV EN/IEC 61000-4-4 input) || 1 kV EN/IEC 61000-4-4 transistor output)
Execution Time For 1 Kinstruction:
0.005 ms
Overvoltage Protection:
with
Maximum Number Of I/O Expansion Module:
7 TM3 IO module (local I/O-Architecture) || 7 TM3 IO module (remote I/O-Architecture)
Product Certifications:
CE || cULus || cULus HazLoc Class I Division 2 CSA 22-2 No 213 || RCM
Communication Service:
OPC UA server (Encrypt) || HTTPs Methods (API) || NTP client
Net Weight:
0.655 kg
Range Of Product:
EcoStruxure Automation Expert
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ambient Air Temperature For Operation:
-20-60°C horizontal installation) || -20-50°C vertical installation) || -20-45°C flat mounting)
Standards:
UL 61010-1 || UL 61010-2-201 || CSA C22.2 No 61010-1 || CSA C22.2 No 61010-2-201 || CSA C22.2 No 213 || ANSI/ISA 12-12-01 || EN 61131-2
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Product Or Component Type:
dPAC module
Electrical Connection:
removable spring terminal block for inputs and outputs || removable spring terminal block for connecting the 24 V DC power supply
Clock Drift:
<= 10 s/month 25-25°C
Resistance To Conducted Disturbances:
10 V 0.15...80 MHz EN/IEC 61000-4-4 || 3 V 0.1...80 MHz || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)
Communication Port Protocol:
EtherNet/IP scanner || Modbus TCP client/server || Modbus TCP IO scanner || Modbus SL client/server
Mounting Support:
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Resistance To Electrostatic Discharge:
4 kV on contact EN/IEC 61000-4-2 || 8 kV on air EN/IEC 61000-4-2
Shock Resistance:
15 gn 11 ms
Ip Degree Of Protection:
IP20
Storage Altitude:
0-3000 m
Surge Withstand:
1 kV power lines (DC) common mode EN/IEC 61000-4-5 || 1 kV shielded cable common mode EN/IEC 61000-4-5 || 0.5 kV relay output differential mode EN/IEC 61000-4-5 || 1 kV input common mode EN/IEC 61000-4-5 || 1 kV transistor output common mode EN/IEC 6
Weight:
0.655 kg
Circularity Profile:
ENVEOLI1904006EN
Data Backed Up:
1 GB built-in flash memory backup of user programs
Insulation:
between supply and internal logic 500 V AC || non-insulated between supply and ground
Relative Humidity:
5-95 %, without condensation in operation) || 5-95 %, without condensation in storage)
Immunity To Microbreaks:
0.01 ms
Depth:
90 mm
Mercury Free:
Yes
Realtime Clock:
with
Rohs Exemption Information:
Yes
China Rohs Regulation:
X
Country of Origin:
Indonesia
Maximum Number Of Connected Devices:
EtherNet/IP <64 || Modbus TCP <64 || Modbus TCP/EtherNet/IP <96
Transmission Rate:
57.6 kbit/s 15-15 m RS485 || 57.6 kbit/s 3-3 m RS232 || 10/100 Mbit/s Ethernet1 || 10/100/1000 Mbit/s Ethernet2
Supply Voltage Limits:
20.4-28.8 V DC
$835.00