Schneider Electric

Schneider Electric TPRPM009 Power module, TeSys island, 15A at AC-1, 9A at AC-3, 4kW, 5hp

(No reviews yet) Write a Review
SKU:
TPRPM009
MPN:
TPRPM009
Condition:
New
Rohs Exemption Information:
Yes
Overvoltage Category:
III
Local Signaling:
for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
Protective Treatment:
TC
Standards:
EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Operating Altitude:
0...6561.68 ft (0...2000 m) without derating
Thermal Protection Adjustment Range:
0.18-9 A
Pollution Degree:
2
Electromagnetic Compatibility:
electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to E
Weight:
0.255 kg
[Ith] Conventional Free Air Thermal Current:
15 A (at 50°C)
Country of Origin:
United States
Reset:
remotely or automatically
Fire Resistance:
960°C UL 94 || 850°C IEC 60695-2-1 || 650°C IEC 60695-2-12
Halogen Content Performance:
Halogen free plastic parts product
Mounting Mode:
horizontal and vertical 35 mm symmetrical DIN rail)
Product Certifications:
CCC || CSA || EAC || UL
Vibration Resistance:
1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
Device Short Name:
TPRPM
Power Dissipation In W:
0.6 W at Ie AC-3
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Eu Rohs Directive:
Compliant with Exemptions
[Ue] Rated Operational Voltage:
<= 690 V AC 47...63 Hz
[Ui] Rated Insulation Voltage:
690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Operation:
-10-50°C without derating || 50-60°C with current derating
Tightening Torque:
1.7-1.7 N.m flat Ø 6 mm || 1.7-1.7 N.m Philips No 2
Shock Resistance:
15 gn 11 ms) IEC 60068-2-27
Protection Type:
thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase loss || rapid restart lockout || phase reversal || phase unbalance || phase sequence || ground current
Thermal Overload Class:
class 5…30
Circularity Profile:
ENVEOLI1904009EN
Sustainable Offer Status:
Green Premium product
Ip Degree Of Protection:
IP20
Connections - Terminals:
screw-clamp terminals 1 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 2 1-4 mm² AWG 16...AWG 12)rigid || screw-clamp terminals 1 1.5-4 mm² AWG 16...AWG 12)flexible without cable end || screw-clamp terminals 2 1.5-4 mm² AWG 16...AWG 12
[Uc] Control Circuit Voltage:
24 V DC supplied by the bus coupler
Net Weight:
0.255 kg
Ambient Air Temperature For Storage:
-25-70°C
Function Available:
upstream voltage presence detection || electronic thermal overload protection || monitoring of currents || control of third party power devices when associated to TPRDG IO module
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Or Component Type:
power module
Maximum Horse Power Rating:
0.33 hp at 120 V AC 60 Hz for 1 phase motors || 1 hp at 240 V AC 60 Hz for 1 phase motors || 2 hp at 208 V AC 60 Hz for 3 phase motors || 2 hp at 240 V AC 60 Hz for 3 phase motors || 5 hp at 480 V AC 60 Hz for 3 phase motors || 7.5 hp at 600 V AC 60
Environmental Disclosure:
ENVPEP1904009EN
Poles Description:
3P
Product Compatibility:
TPRBC bus coupler || TPRDG digital IO module || TPRAN analog IO module
Motor Power Kw:
2.2 kW at 230 V AC 50 Hz || 4 kW at 380...415 V AC 50 Hz || 4 kW at 440 V AC 50 Hz || 5.5 kW at 500 V AC 50 Hz || 5.5 kW at 690 V AC 50 Hz
Depth:
115 mm
$200.00

Description

TeSys island power module, 3 poles, 9A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 9A and motors up to 4kW@400V / 5hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.18-9A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose