Schneider Electric VLS1P063D2S Disconnect switch, TeSys VLS, additional pole, 63A, for 30A and 63A switch, size 2, door mount
Schneider Electric
$48.21
These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P063D2 door mount switch. This fourth pole adder for door mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 60 A current rating. Fourth pole adder pole is 3.94 inches tall, 0.91 inches wide and 1.91 inches deep. It weighs 0.24 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.
- Range Compatibility:
- TeSys TeSys VARIO LS VLS3P
- Mounting Location:
- right || left
- Rohs Exemption Information:
- Yes
- Device Short Name:
- VLS1P
- Tightening Torque:
- power circuit 5-6 N.m screw clamp terminals
- Mechanical Robustness:
- vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
- Network Type:
- AC
- Electrical Durability:
- 30000 cycles AC-21
- [Icm] Rated Short-Circuit Making Capacity:
- 3550 A 690 V
- Performance Level:
- high performance
- Ambient Air Temperature For Operation:
- -25-55°C
- Country of Origin:
- Italy
- Reach Free Of Svhc:
- Yes
- Depth:
- 48.6 mm
- [Icw] Rated Short-Time Withstand Current:
- 2500 A 690 V 1 s
- Product Certifications:
- cULus || GL
- Standards:
- UL98 || CSA C22.2 No 4 || IEC 60947-3
- [Ie] Rated Operational Current:
- 60 A Ue: 600 V UL98 || 63 A AC-21A Ue: 400 V || 63 A AC-21A Ue: 500 V || 63 A AC-21A Ue: 690 V || 63 A AC-22A Ue: 400 V || 63 A AC-22A Ue: 500 V || 63 A AC-22A Ue: 690 V || 63 A AC-23A Ue: 400 V || 63 A AC-23A Ue: 500 V || 47 A AC-23A Ue: 690 V
- Product Or Component Type:
- additional pole
- Range:
- TeSys
- Rated Operational Power In W:
- 30 kW 400 V AC-23A) || 45 kW 500 V AC-23A) || 45 kW 690 V AC-23A)
- Mercury Free:
- Yes
- Rated Conditional Short-Circuit Current:
- 50 kA 400 V 63 A gG
- [Ith] Conventional Free Air Thermal Current:
- 63 A (at 55°C)
- Poles Description:
- 1P
- Intermittent Duty Class:
- class 120 - 60 %
- Toxic Heavy Metal Free:
- Yes
- Suitability For Isolation:
- yes
- Net Weight:
- 0.11 kg
- Mounting Support:
- door
- Connections - Terminals:
- power circuit screw clamp terminals 50-50 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible - without cable end
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Contact Operation:
- simultaneous
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Ithe] Conventional Enclosed Thermal Current:
- 63 A
- Making Capacity:
- 94.5 A 690 V AC-21A || 189 A 690 V AC-22A || 630 A 690 V AC-23A
- Weight:
- 0.11 kg
- Mechanical Durability:
- 30000 cycles
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz
- Network Frequency:
- 50/60 Hz
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Breaking Capacity:
- 94.5 A 690 V AC-21A) || 189 A 690 V AC-22A) || 504 A 690 V AC-23A)
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Color:
- Gray
- Eu Rohs Directive:
- Compliant