Breaking Capacity:
120 A 690 V AC-22A) || 320 A 690 V AC-23A) || 94.5 A 690 V AC-21A)
Intermittent Duty Class:
class 120 - 60 %
[Ithe] Conventional Enclosed Thermal Current:
45 A
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Icw] Rated Short-Time Withstand Current:
800 A 690 V 1 s
Device Short Name:
VLS1P
Mechanical Durability:
100000 cycles
Mechanical Robustness:
vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
Mercury Free:
Yes
Ambient Air Temperature For Operation:
-25-55°C
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Weight:
0.04 kg
Toxic Heavy Metal Free:
Yes
Poles Description:
1P
Eu Rohs Directive:
Compliant
Contact Operation:
simultaneous
Depth:
43.6 mm
Mounting Location:
left || right
Color:
Gray
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Certifications:
cULus || GL
Standards:
UL 508 || CSA C22.2 No 14 || IEC 60947-3
Network Frequency:
50/60 Hz
Making Capacity:
120 A 690 V AC-22A || 400 A 690 V AC-23A || 94.5 A 690 V AC-21A
Performance Level:
high performance
Range Compatibility:
TeSys TeSys VARIO LS VLS3P
Network Type:
AC
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz
Net Weight:
0.04 kg
Country of Origin:
Italy
[Ith] Conventional Free Air Thermal Current:
63 A (at 55°C)
Rated Conditional Short-Circuit Current:
50 kA 400 V 63 A gG
Range:
TeSys
Tightening Torque:
power circuit 1.8-2 N.m screw clamp terminals
Contacts Type And Composition:
1 NO
Reach Free Of Svhc:
Yes
Fire Resistance:
960°C IEC 60695-2-11
Mounting Support:
DIN rail
[Icm] Rated Short-Circuit Making Capacity:
1128 A 690 V
Suitability For Isolation:
yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Connections - Terminals:
power circuit screw clamp terminals 10-10 mm² solid || power circuit screw clamp terminals 16-16 mm² flexible - without cable end
Rated Operational Power In W:
22 kW 400 V AC-23A) || 22 kW 500 V AC-23A) || 22 kW 690 V AC-23A)
$45.64

Description

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P063R1 DIN rail mount switch. This fourth pole adder for DIN rail mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 60 A current rating. Fourth pole adder is 3.07 inches tall, 0.47 inches wide and 1.72 inches deep. It weighs 0.09 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.