Schneider Electric VLS1P100R2S Disconnect switch, TeSys VLS, additional pole, 100A, for 100A switch, size 2, DIN rail
Schneider Electric
$50.20
These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This fourth pole adder can be added to a VLS3P100R2 door mount switch. This fourth pole adder for DIN rail mounted devices can be mounted on the right or left hand side. This simultaneous closing adder pole has one normally open contact The operational voltage of this fourth pole adder module is 600 Vac 50/60 Hz. This fourth pole adder module has a 100 A current rating. Fourth pole adder pole is 3.94 inches tall, 0.91 inches wide and 1.73 inches deep. It weighs 0.24 lbs. This fourth pole adder block is cULus Listed and meets IEC 60947-3 requirements.
- Fire Resistance:
- 960°C IEC 60695-2-11
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz
- Mounting Location:
- right || left
- Performance Level:
- high performance
- Product Or Component Type:
- additional pole
- [Ithe] Conventional Enclosed Thermal Current:
- 100 A
- Color:
- Gray
- Standards:
- UL98 || CSA C22.2 No 4 || IEC 60947-3
- Height:
- 100 mm
- Network Frequency:
- 50/60 Hz
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- [Icw] Rated Short-Time Withstand Current:
- 2500 A 690 V 1 s
- Eu Rohs Directive:
- Compliant
- Mounting Support:
- DIN rail
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Intermittent Duty Class:
- class 120 - 60 %
- Rohs Exemption Information:
- Yes
- Network Type:
- AC
- Suitability For Isolation:
- yes
- Rated Operational Power In W:
- 55 kW 400 V AC-23A) || 45 kW 500 V AC-23A) || 45 kW 690 V AC-23A)
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Toxic Heavy Metal Free:
- Yes
- Contact Operation:
- simultaneous
- [Ith] Conventional Free Air Thermal Current:
- 100 A (at 55°C)
- Mechanical Durability:
- 30000 cycles
- Electrical Durability:
- 30000 cycles AC-21
- Breaking Capacity:
- 150 A 690 V AC-21A) || 300 A 690 V AC-22A) || 800 A 690 V AC-23A)
- Poles Description:
- 1P
- Net Weight:
- 0.11 kg
- Making Capacity:
- 150 A 690 V AC-21A || 300 A 690 V AC-22A || 1000 A 690 V AC-23A
- Mechanical Robustness:
- vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
- Product Certifications:
- cULus || GL
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Reach Free Of Svhc:
- Yes
- Device Short Name:
- VLS1P
- Contacts Type And Composition:
- 1 NO
- Tightening Torque:
- power circuit 5-6 N.m screw clamp terminals
- Rated Conditional Short-Circuit Current:
- 50 kA 400 V 100 A gG
- Range Compatibility:
- TeSys TeSys VARIO LS VLS3P
- [Ie] Rated Operational Current:
- 100 A Ue: 600 V UL98 || 100 A AC-21A Ue: 400 V || 100 A AC-21A Ue: 500 V || 100 A AC-21A Ue: 690 V || 100 A AC-22A Ue: 400 V || 100 A AC-22A Ue: 500 V || 100 A AC-22A Ue: 690 V || 100 A AC-23A Ue: 400 V || 80 A AC-23A Ue: 500 V || 47 A AC-23A Ue: 690
- Country of Origin:
- Italy
- Range:
- TeSys
- Depth:
- 43.9 mm
- [Icm] Rated Short-Circuit Making Capacity:
- 3550 A 690 V
- Weight:
- 0.11 kg
- Connections - Terminals:
- power circuit screw clamp terminals 50-50 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible - without cable end
- Ambient Air Temperature For Operation:
- -25-55°C