Schneider Electric

Schneider Electric VLS3P100D2 Disconnect switch, TeSys VLS, body switch, 100A, 50HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount

(No reviews yet) Write a Review
SKU:
VLS3P100D2
MPN:
VLS3P100D2
Condition:
New
Rated Conditional Short-Circuit Current:
50 kA 400 V 100 A gG
Breaking Capacity:
150 A 690 V AC-21A) || 300 A 690 V AC-22A) || 800 A 690 V AC-23A)
Product Or Component Type:
switch body
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Fire Resistance:
960°C IEC 60695-2-11
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Name:
TeSys VARIO LS
Poles Description:
3P
[Ie] Rated Operational Current:
100 A Ue: 600 V UL98 || 100 A AC-21A Ue: 400 V || 100 A AC-21A Ue: 500 V || 100 A AC-21A Ue: 690 V || 100 A AC-22A Ue: 400 V || 100 A AC-22A Ue: 500 V || 100 A AC-22A Ue: 690 V || 100 A AC-23A Ue: 400 V || 80 A AC-23A Ue: 500 V || 47 A AC-23A Ue: 690
Ambient Air Temperature For Operation:
-25-55°C
Mounting Support:
door
Making Capacity:
1000 A 690 V AC-23A || 150 A 690 V AC-21A || 300 A 690 V AC-22A
Reach Free Of Svhc:
Yes
Eu Rohs Directive:
Compliant
Contacts Type And Composition:
3 NO
Device Short Name:
VLS3P
Network Frequency:
50/60 Hz
Color:
Gray
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 508
Performance Level:
high performance
Toxic Heavy Metal Free:
Yes
Mercury Free:
Yes
[Icm] Rated Short-Circuit Making Capacity:
3550 A 690 V
Tightening Torque:
power circuit 5-6 N.m screw clamp terminals
Network Type:
AC
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Standards:
UL98 || CSA C22.2 No 4 || IEC 60947-3
Net Weight:
0.365 kg
Rated Operational Power In W:
55 kW 400 V AC-23A) || 45 kW 500 V AC-23A) || 45 kW 690 V AC-23A)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Depth:
100 mm
Weight:
0.365 kg
Intermittent Duty Class:
class 120 - 60 %
Country of Origin:
Italy
[Icw] Rated Short-Time Withstand Current:
2500 A 690 V 1 s
Product Certifications:
cULus || GL
Mechanical Robustness:
vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
Electrical Durability:
30000 cycles AC-21
[Ithe] Conventional Enclosed Thermal Current:
100 A
Rohs Exemption Information:
Yes
Range:
TeSys
Connections - Terminals:
power circuit screw clamp terminals 50-50 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible - without cable end
[Ith] Conventional Free Air Thermal Current:
100 A (at 55°C)
Mechanical Durability:
30000 cycles
$145.38

Description

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This 100A disconnect switch has 3 normally open poles and mounts directly in the enclosure door. Per UL and CSA this this disconnect switch has a 5 HP rating at 120 VAC and a 10 HP at 240 VAC single phase. Per UL and CSA this disconnect switch has a 30 HP rating at 200 to 208 VAC and 240 VAC, a 50 HP rating at 480 VAC and 600 VAC three phase. Per UL508A this this disconnect switch has up to a 50 kA at 600 V short circuit current rating (SCCR) with a 100A Type J fuse maximum. Per IEC requirements, this disconnect switch has a 55 kW rating at 400 V, a 45 kW rating at 500 V and a 45 kW rating at 690V three phase. The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 12 AWG to 1 AWG. This disconnect switch is 3.94 inches tall, 2.76 inches wide and 2.76 inches deep. The switch weighs 0.80 lbs. There are many handles and accessories available this TeSys VLS disconnect switch. This TeSys VLS disconnect switch is UL Listed per UL98, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.