Schneider Electric

Schneider Electric VLS3P125D2 Disconnect switch, TeSys VLS, body switch, 125A, 60HP at 480VAC, UL98, three phase, 50kA SCCR, size 2, door mount

(No reviews yet) Write a Review
SKU:
VLS3P125D2
MPN:
VLS3P125D2
Condition:
New
Poles Description:
3P
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Icw] Rated Short-Time Withstand Current:
2500 A 690 V 1 s
Net Weight:
0.365 kg
Weight:
0.365 kg
Ip Degree Of Protection:
IP20 conforming to IEC 60529
Color:
Gray
[Ithe] Conventional Enclosed Thermal Current:
100 A
Fire Resistance:
960°C IEC 60695-2-11
Network Type:
AC
Breaking Capacity:
187.5 A 690 V AC-21A) || 375 A 690 V AC-22A) || 1000 A 690 V AC-23A)
[Ie] Rated Operational Current:
100 A Ue: 600 V UL98 || 125 A AC-21A Ue: 400 V || 125 A AC-21A Ue: 500 V || 125 A AC-21A Ue: 690 V || 125 A AC-22A Ue: 400 V || 125 A AC-22A Ue: 500 V || 125 A AC-22A Ue: 690 V || 125 A AC-23A Ue: 400 V || 100 A AC-23A Ue: 500 V || 47 A AC-23A Ue: 69
Product Certifications:
cULus || GL
[Ith] Conventional Free Air Thermal Current:
125 A (at 55°C)
Depth:
100 mm
Device Short Name:
VLS3P
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Country of Origin:
Italy
Performance Level:
high performance
Reach Free Of Svhc:
Yes
Mechanical Durability:
30000 cycles
Mounting Support:
door
Range:
TeSys
Mechanical Robustness:
vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
Product Name:
TeSys VARIO LS
Contacts Type And Composition:
3 NO
Product Or Component Type:
switch body
Tightening Torque:
power circuit 5-6 N.m screw clamp terminals
Standards:
UL98 || CSA C22.2 No 4 || IEC 60947-3
Ambient Air Temperature For Operation:
-25-55°C
Making Capacity:
1250 A 690 V AC-23A || 187.5 A 690 V AC-21A || 375 A 690 V AC-22A
Mercury Free:
Yes
[Icm] Rated Short-Circuit Making Capacity:
3550 A 690 V
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 508
Intermittent Duty Class:
class 120 - 60 %
Connections - Terminals:
power circuit screw clamp terminals 50-50 mm² solid || power circuit screw clamp terminals 70-70 mm² flexible - without cable end
Eu Rohs Directive:
Compliant
Rated Conditional Short-Circuit Current:
50 kA 400 V 125 A gG
Electrical Durability:
30000 cycles AC-21
Toxic Heavy Metal Free:
Yes
Network Frequency:
50/60 Hz
Rated Operational Power In W:
55 kW 400 V AC-23A) || 45 kW 500 V AC-23A) || 45 kW 690 V AC-23A)
$220.07

Description

These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This 125A disconnect switch has 3 normally open poles and mounts directly in the enclosure door. Per UL and CSA this this disconnect switch has a 7.5 HP rating at 120 VAC and a 10 HP at 240 VAC single phase. Per UL and CSA this disconnect switch has a 30 HP rating at 200 to 208 VAC and 240 VAC, a 60 HP rating at 480 VAC and 600 VAC three phase. Per UL508A this this disconnect switch has up to a 50 kA at 600 V short circuit current rating (SCCR) with a 100A Type J fuse maximum. Per IEC requirements, this disconnect switch has a 55 kW rating at 400 V, a 45 kW rating at 500 V and a 45 kW rating at 690V three phase. The screw clamp terminals will accept 10 mm solid or 16 mm stranded wire. The clamps will also accept solid or stranded wire from 12 AWG to 1 AWG. This disconnect switch is 3.94 inches tall, 2.76 inches wide and 2.76 inches deep. The switch weighs 0.80 lbs. There are many handles and accessories available this TeSys VLS disconnect switch. This TeSys VLS disconnect switch is UL Listed per UL98, CSA certified per CSA 22.2 and meets IEC 60947-3 requirements.
View AllClose