Schneider Electric VLSA11RS Disconnect switch, TeSys VLS, auxiliary contact block, 1 normally closed and 1 normally open, DIN rail
Schneider Electric
$25.16
These TeSys VLS disconnect switches are for integration into control systems in applications like material handling, HVAC, pumping, solar energy, mining and many more. This family of disconnect switches has switches ranging from 16A to 125A. The 16A, 25A, 32A, 40A and 63A disconnect switches are UL508 motor disconnect switches rated. The 30A, 63A, 80A, 100A and 125A disconnect switches are UL98 non fusible disconnect switch rated. This auxiliary contact can be added to a VLS3P016D1, VLS3P025D1, VLS3P032D1, VLS3P040D1 or VLS3P063D1 door mount switch. This auxiliary contact can also be added to a VLS3P030D2, VLS3P063D2, VLS3P080D2, VLS3P100D2 or VLS3P125D2 door mount switch. This auxiliary contact can be mounted on the right or left hand side. This auxiliary contact has one normally open early break contact. The operational voltage of this auxiliary contact is 600 V. This auxiliary contact block has A600 and Q600 current ratings. The screw clamp terminals will accept 18 AWG to 6 AWG wire. This auxiliary contact is 2.86 inches tall, 0.35 inches wide and 1.82 inches deep. The switch weighs 0.07 lbs. This auxiliary contact module is cULus Listed and meets IEC 60947-3 requirements.
- Mercury Free:
- Yes
- Ambient Air Temperature For Operation:
- -25-55°C
- Contact Operation:
- simultaneous 1 NC || simultaneous 1 NO
- Weight:
- 0.03 kg
- Product Certifications:
- cULus || GL
- Connections - Terminals:
- control circuit screw clamp terminals 2.5-2.5 mm² flexible - without cable end
- Product Or Component Type:
- auxiliary contact block
- Toxic Heavy Metal Free:
- Yes
- Contacts Type And Composition:
- 1 NC + 1 NO
- Color:
- Gray
- Network Frequency:
- 50/60 Hz
- Device Short Name:
- VLSA
- Depth:
- 46.2 mm
- Rohs Exemption Information:
- Yes
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Reach Free Of Svhc:
- Yes
- Range Compatibility:
- TeSys TeSys VARIO LS VLSA || TeSys TeSys VARIO LS VLS3P || TeSys TeSys VARIO LS VLS1P
- Mechanical Robustness:
- vibrations 2...100 Hz Fc 0.7 g) IEC 60068-2-6 || shocks 11 ms Ea 15 gn) IEC 60068-2-27
- Net Weight:
- 0.03 kg
- Network Type:
- DC || AC
- Standards:
- UL 508 || CSA C22.2 No 14 || IEC 60947-3 || IEC 60947-5
- [Ithe] Conventional Enclosed Thermal Current:
- 0.416666666666667
- Minimum Output Current:
- 10 mA
- Mounting Location:
- right || left
- Performance Level:
- high performance
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Eu Rohs Directive:
- Compliant
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Range:
- TeSys
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Tightening Torque:
- control circuit 0.8-1 N.m screw clamp terminals
- Minimum Output Voltage:
- 5 V
- Fire Resistance:
- 850°C IEC 60695-2-11
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz
- [Ie] Rated Operational Current:
- 6 A AC-15)24 V AC || 6 A AC-15)48 V AC || 6 A AC-15)127 V AC || 3 A AC-15)240 V AC || 3 A DC-13)24 V DC || 1.5 A DC-13)48 V DC || 0.55 A DC-13)127 V DC || 0.27 A DC-13)240 V DC
- Mounting Support:
- DIN rail
- Country of Origin:
- Italy
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 55°C)