Schneider Electric VN12 Switch body,TeSys Control,3 poles,12A,compact size
Schneider Electric
$52.00
VN12 is a 3-pole switch body for TeSys Vario switch-disconnector from Schneider Electric for motor applications 4kW@400V AC-23. It requires an operating handle and extension shaft to form a complete unit for enclosure mounting. VN12 is a 3-pole switch body for TeSys Vario switch-disconnector from Schneider Electric. Rated 12A 690V, it is used in motor applications 4kW@400V AC-23. It requires an operating handle and extension shaft to form a main or emergency stop switch disconnector. Add-on modules (main pole, neutral pole, earthing module, auxiliary contacts) can complete the assembly. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach). Vario 3-pole switch body for rotary switch disconnector assemblies. Rated for 690V AC operation, DC operation is permitted until 250V, performance depending on the number of contacts in series. Possible attachment of 2 add-on poles (1 on each side) , main (VZN12), neutral (VZN11), earthing (VZN14), auxiliary (VZN05, VZN06).
- Electrical Durability:
- 30000 cycles DC-1...5 || 50000 cycles AC-21
- Pvc Free:
- Yes
- Weight:
- 0.11 kg
- Warranty:
- 18 months
- Rohs Exemption Information:
- Yes
- Contacts Type And Composition:
- 3 NO
- [Icw] Rated Short-Time Withstand Current:
- 140 A 400 V 1 s
- Rated Conditional Short-Circuit Current:
- 6 kA 400 V 12 A aM || 6 kA 400 V 12 A gG
- Depth:
- 62 mm
- Net Weight:
- 0.11 kg
- Making Capacity:
- 120 A 400 V AC-21A || 120 A 400 V AC-22A || 120 A 400 V AC-23A
- Performance Level:
- standard
- [Ithe] Conventional Enclosed Thermal Current:
- 0.416666666666667
- Circularity Profile:
- N/A
- [Ue] Rated Operational Voltage:
- 690 V AC 50/60 Hz
- Protective Treatment:
- TC
- Mercury Free:
- Yes
- Network Frequency:
- 50/60 Hz
- Standards:
- IEC 60947-3
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ith] Conventional Free Air Thermal Current:
- 0
- [Ie] Rated Operational Current:
- 8.1 A AC-23)400 V
- Breaking Capacity:
- 120 A 400 V AC-22A) || 120 A 400 V AC-23A) || 120 A 400 V AC-21A)
- Product Or Component Type:
- switch body
- Ambient Air Temperature For Operation:
- -20-50°C
- Network Type:
- DC || AC
- Environmental Disclosure:
- ENVPEP2211017
- Mounting Support:
- symmetrical rail
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV
- [Icm] Rated Short-Circuit Making Capacity:
- 0.5 kA 400 V at Ipeak
- Intermittent Duty Class:
- 30
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Connections - Terminals:
- power circuit screw clamp terminals 4-4 mm² solid || power circuit screw clamp terminals 4-4 mm² flexible - with cable end
- Tightening Torque:
- power circuit 7-7 N.m screw clamp terminals
- Rated Operational Power In W:
- 3 kW 400...415 V AC-3) || 4 kW 500 V AC-3) || 4 kW 690 V AC-3) || 1.5 kW 230...240 V AC-3) || 5.5 kW 500 V AC-23A) || 7.5 kW 690 V AC-23A) || 3 kW 230...240 V AC-23A) || 4 kW 400...415 V AC-23A)
- Mechanical Robustness:
- vibrations 10...150 Hz 5 gn) IEC 60068-2-6 || shocks 11 ms 15 gn) IEC 60068-2-27
- Sustainable Offer Status:
- Green Premium product
- Eu Rohs Directive:
- Compliant with Exemptions
- Ip Degree Of Protection:
- IP20 conforming to IEC 60529
- Fire Resistance:
- 960°C IEC 60695-2-1
- Range:
- TeSys
- Poles Description:
- 3P
- Country of Origin:
- Czechia
- Halogen Content Performance:
- Halogen free product
- Product Certifications:
- UL || CSA || GL || UKCA