Schneider Electric XPSMCMC10804G Safety controller, Modicon MCM, 8 inputs 4 outputs, monitors expansion modules, spring
Schneider Electric
$582.19
This Modicon MCM safety controller CPU is supplied with 24Vdc, has 8 safe digital inputs, 4 start/restart interlock inputs, 4 single channel OSSD, 4 test outputs, 4 configurable status outputs, fitted with captive spring clamp terminals. It embeds a Mini USB 2.0 connector to receive the configuration done with the software EcoStruxure Machine Expert - HVAC. It is an appropriate solution for machines with a small number of safety functions requiring the configuration flexibility of a safety controller. It can be used as standalone or with fourteen expansion modules. The system is expandable up to 128 inputs, 16 outputs and up to 32 diagnostic status outputs, ideal for machines requiring multiple safety function monitoring. This safety controller CPU figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, communication, master enable, restart signal, output channels). It is a CPU with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with spring clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. It weighs 0.25kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safety controller CPU instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
- Number Of Outputs:
- 4 safety outputs OSSD contactor/drive connection || 4 test line control outputs || 4 configurable diagnostic connection
- Device Short Name:
- XPSMCM
- Pollution Degree:
- 2
- Discrete Output Type:
- PNP
- Range Of Product:
- Modicon Safety automation
- [Us] Rated Supply Voltage:
- 24 V - 20...20 % DC
- Power Dissipation In W:
- 3 W
- Discrete Input Voltage:
- 24 V
- Depth:
- 114.5 mm
- Inductive Load:
- 2.4 mH
- Electrical Connection:
- spring terminal
- Local Signaling:
- 1 LED green PWR power ON || 1 LED green RUN RUN (status) || 1 LED red E IN internal error || 1 LED red E EX external error || 1 LED orange COM communication || 1 LED blue EN master enable || 8 LEDs yellow IN input status || 2 LEDs green/red OUT outpu
- Reach Free Of Svhc:
- Yes
- Shock Resistance:
- 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV IEC 61800-5-1
- Width:
- 22.5 mm
- Ambient Air Temperature For Storage:
- -20-85°C
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- China Rohs Regulation:
- X
- Discrete Input Current:
- 400 mA
- Load Capacitance:
- 0.82µF
- Standards:
- IEC 61496-1 || ISO 13849-1 || IEC 61508 || IEC 61800-5-1 || IEC 62061
- Country of Origin:
- Italy
- Safety Level:
- can reach category 4 ISO 13849-1 || can reach PL = e ISO 13849-1 || type 4 IEC 61496-1 || SILCL 3 IEC 62061
- Function Of Module:
- emergency stop ISO 13850 || guard monitoring EN/ISO 14119 || enabling switch monitoring IEC 60947-5-1 || light curtain monitoring IEC 61496-1 || foot switch monitoring IEC 60947-5-1 || light curtain monitoring EN/ISO 14119 || switch monitoring EN 574
- Ip Degree Of Protection:
- IP20
- Rohs Exemption Information:
- Yes
- Service Life:
- 20 year(s)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Net Weight:
- 0.155 kg
- Relative Humidity:
- 10-95 %
- Product Certifications:
- TÜV || RCM || cULus
- Quality Labels:
- CE
- Insulation:
- 250 V AC between power supply and housing IEC 61800-5-1
- Integrated Connection Type:
- backplane expansion bus || USB 2.0 port
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Discrete Output Current:
- 400 mA
- Mounting Support:
- omega 35 mm DIN rail EN 50022
- Cable Cross Section:
- 0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end || 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end || 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel || 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end,
- Overvoltage Category:
- II
- Connections - Terminals:
- 2 spring terminals, removable terminal block || 1 spring terminals, removable terminal block
- Weight:
- 0.155 kg
- Safety Reliability Data:
- PFHd = 1.35E-8 1/h high || DC > 99 % || MTTFd < 100 years
- Mercury Free:
- Yes
- Synchronisation Time Between Inputs:
- < 0.5 ms
- Data Storage Equipment:
- SD card optional)
- Discrete Input Type:
- safety input || PNP