This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch or Safety light curtain. The safety relay is powered with 48-240V AC/DC and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 ON/OFF configurable pulsed outputs, 3 NO safety outputs, and 1 solid state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILC L 3 conforming to IEC 62061, and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÜV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
- Ambient Air Temperature For Storage:
- -25-85°C
- Minimum Output Voltage:
- 15 V relay output
- Depth:
- 120 mm
- Circularity Profile:
- ENVEOLI1811003EN
- [Ie] Rated Operational Current:
- 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
- Mercury Free:
- Yes
- Country of Origin:
- Indonesia
- Associated Fuse Rating:
- 10 A gG NO relay output circuit IEC 60947-1
- Input/Output Type:
- semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
- Safety Module Application:
- monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
- Number Of Inputs:
- 2 safety input 24 V DC 5
- Sustainable Offer Status:
- Green Premium product
- Safety Level:
- can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508
- [Ith] Conventional Free Air Thermal Current:
- 0.333333333333333
- Function Of Module:
- emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE
- Minimum Output Current:
- 10 mA relay output
- Maximum Line Resistance:
- 500 Ohm
- [Uimp] Rated Impulse Withstand Voltage:
- 4 kV II IEC 60947-1
- Environmental Disclosure:
- ENVPEP1811003EN
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Power Consumption In Va:
- 6.5 VA 240 V AC 50/60 Hz
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Relative Humidity:
- 5-95 % non-condensing
- Range Of Product:
- Harmony Safety Automation
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ip Degree Of Protection:
- IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
- Standards:
- IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
- Input Protection Type:
- internal, electronic
- Rohs Exemption Information:
- Yes
- Maximum Response Time On Input Open:
- 20 ms
- Pvc Free:
- Yes
- Synchronisation Time Between Inputs:
- 0.5 s || 2 s || 4 s
- Net Weight:
- 0.200 kg
- Type Of Start:
- automatic/manual/monitored
- Input Compatibility:
- normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation:
- X
- Number Of Outputs:
- 3 on/off configurable pulsed output
- Power Consumption In W:
- 3.0 W 48 V DC
- Local Signaling:
- for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S22 LED (yellow)
- Weight:
- 0.200 kg
- [Us] Rated Supply Voltage:
- 48...240 V AC/DC - 10...10 %
- Connections - Terminals:
- removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || remova
- Electrical Circuit Type:
- NC pair || PNP pair || antivalent pair || OSSD pair
- Mounting Support:
- 35 mm symmetrical DIN rail
- Safety Module Name:
- XPSUAF