Safety Module Application:
monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || monitoring of pressure-sensitive 4-wire protective devices
Maximum Line Resistance:
500 Ohm
Auxiliary Contact Composition:
3 NO immediate || 1 NC configurable || 3 NO configurable
Safety Module Name:
XPSUAT
Net Weight:
0.350 kg
[Us] Rated Supply Voltage:
24 V AC - 15...10 % || 24 V DC - 20...20 %
Type Of Start:
automatic/manual/monitored
Time Delay Range:
0...900 s off
Connections - Terminals:
removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || remova
Relative Humidity:
5-95 % non-condensing
Standards:
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
[Ith] Conventional Free Air Thermal Current:
16 A
Product Certifications:
TÃœV || cULus
[Ie] Rated Operational Current:
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally clo
Pvc Free:
Yes
Country of Origin:
Indonesia
Maximum Response Time On Input Open:
20 ms
Circularity Profile:
ENVEOLI1811003EN
Function Of Module:
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE
Number Of Inputs:
2 positive safety input 24 V DC 8 || 1 negative safety input
Minimum Output Voltage:
24 V relay output
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Safety Reliability Data:
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.94E-09 for SS0 ISO 13849-1 || PFHd = 0.95E-09 for SS1 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.94E-09 for SS0 IEC 62061 || PFHd = 0.95E-09 for SS1 IEC 62061 || SFF > 99% IEC 62
Input Protection Type:
internal, electronic
Environmental Disclosure:
ENVPEP1811003EN
Input Compatibility:
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
[Ui] Rated Insulation Voltage:
250 V 2)IEC 60947-1
Depth:
120 mm
Weight:
0.350 kg
China Rohs Regulation:
X
Number Of Outputs:
4 on/off configurable pulsed output
Synchronisation Time Between Inputs:
0.5 s || 2 s || 4 s
Range Of Product:
Harmony Safety Automation
Safety Level:
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay c
[Uimp] Rated Impulse Withstand Voltage:
4 kV II IEC 60947-1
Input/Output Type:
pulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related || semiconductor output 24 V DC, 20 mA Z2, not safety-related
Associated Fuse Rating:
10 A gG NO relay output circuit IEC 60947-1
Ip Degree Of Protection:
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Power Consumption In W:
3 W 24 V DC
Minimum Output Current:
20 mA relay output
Mercury Free:
Yes
Power Consumption In Va:
6.5 VA 24 V AC 50/60 Hz
Electrical Circuit Type:
NC pair || PNP pair || antivalent pair || OSSD pair
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
$593.99

Description

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP, NPN sensor, RFID safety switch, Safety light curtain or Sensing mat/edges. The safety relay is powered with 24V AC/DC, and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 positive 1 negative safety inputs, 4 ON/OFF configurable pulsed outputs, 3 NO immediate, 3 NO configurable, 1 NC configurable safety outputs, 2 solid state diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÃœV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.