Safety Module Application:
monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || monitoring of pressure-sensitive 4-wire protective devices
Ip Degree Of Protection:
IP54 mounting area)IEC 60947-1 || IP40 housing)IEC 60947-1 || IP20 terminals)IEC 60947-1
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP1811003EN
Safety Module Name:
XPSUAT
Mounting Support:
35 mm symmetrical DIN rail
Safety Level:
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay c
Type Of Start:
automatic/manual/monitored
[Us] Rated Supply Voltage:
48...240 V AC/DC - 10...10 %
Associated Fuse Rating:
10 A gG NO relay output circuit IEC 60947-1
Product Or Component Type:
safety module
Synchronisation Time Between Inputs:
0.5 s || 2 s || 4 s
Rohs Exemption Information:
Yes
China Rohs Regulation:
X
Electrical Circuit Type:
NC pair || PNP pair || antivalent pair || OSSD pair
Country of Origin:
Indonesia
Pvc Free:
Yes
Weight:
0.350 kg
Minimum Output Current:
20 mA relay output
Relative Humidity:
5-95 % non-condensing
[Uimp] Rated Impulse Withstand Voltage:
4 kV II IEC 60947-1
Circularity Profile:
ENVEOLI1811003EN
Ambient Air Temperature For Storage:
-25-85°C
Time Delay Range:
0...900 s off
[Ith] Conventional Free Air Thermal Current:
16 A
Minimum Output Voltage:
24 V relay output
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Function Of Module:
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE
Number Of Outputs:
4 on/off configurable pulsed output
Depth:
120 mm
Product Certifications:
TÃœV || cULus
Mercury Free:
Yes
Power Consumption In Va:
10 VA 240 V AC 50/60 Hz
Power Consumption In W:
4 W 48 V DC
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Connections - Terminals:
removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || remova
Maximum Response Time On Input Open:
20 ms
Safety Reliability Data:
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 1.47E-09 for SS0 ISO 13849-1 || PFHd = 1.48E-09 for SS1 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 1.47E-09 for SS0 IEC 62061 || PFHd = 1.48E-09 for SS1 IEC 62061 || SFF > 99% IEC 62
Auxiliary Contact Composition:
1 NC configurable || 3 NO configurable || 3 NO immediate
[Ie] Rated Operational Current:
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally clo
Maximum Line Resistance:
500 Ohm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
Harmony Safety Automation
Input Protection Type:
internal, electronic
Standards:
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
Net Weight:
0.350 kg
$653.39

Description

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP, NPN sensor, RFID safety switch, Safety light curtain or Sensing mat/edges. The safety relay is powered with 48-240V AC/DC and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 positive 1 negative safety inputs, 4 ON/OFF configurable pulsed outputs, 3 NO immediate, 3 NO configurable, 1 NC configurable safety outputs, 2 solid state diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÃœV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.