[Us] Rated Supply Voltage:
24 V AC - 15...10 % || 24 V DC - 20...20 %
[Ith] Conventional Free Air Thermal Current:
16 A
Power Consumption In Va:
10.5 VA 24 V AC 50/60 Hz
China Rohs Regulation:
X
Weight:
0.350 kg
Auxiliary Contact Composition:
3 NO + 1 NC
Safety Module Application:
monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring
Safety Reliability Data:
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 0.88E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 0.88E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 0.88E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type =
Range Of Product:
Harmony Safety Automation
Local Signaling:
for power ON LED (green) || for error LED (red) || for start LED (yellow) || for safety status LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23
Circularity Profile:
ENVEOLI1811003EN
Type Of Start:
automatic/manual/monitored
Minimum Output Current:
10 mA relay output
Electrical Circuit Type:
NC pair || PNP pair || antivalent pair || OSSD pair
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Input Protection Type:
internal, electronic
Ip Degree Of Protection:
IP20 terminals)IEC 60947-1 || IP40 housing)IEC 60947-1 || IP54 mounting area)IEC 60947-1
Input/Output Type:
semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related
[Uimp] Rated Impulse Withstand Voltage:
4 kV II IEC 60947-1
Ambient Air Temperature For Operation:
-25-50°C at 24 V AC || -25-55°C at 24 V DC
Ambient Air Temperature For Storage:
-25-85°C
Power Consumption In W:
4.5 W 24 V DC
Product Or Component Type:
safety module
Standards:
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP1811003EN
Net Weight:
0.350 kg
[Ie] Rated Operational Current:
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally clo
Number Of Inputs:
6 safety input 24 V DC 5
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Sustainable Offer Status:
Green Premium product
Width:
45 mm
Rohs Exemption Information:
Yes
Connections - Terminals:
removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || remova
Safety Module Name:
XPSUDN
Minimum Output Voltage:
12 V relay output
Maximum Response Time On Input Open:
20 ms
Country of Origin:
France
Pvc Free:
Yes
Associated Fuse Rating:
10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
Mounting Support:
35 mm symmetrical DIN rail
Relative Humidity:
5-95 % non-condensing
Depth:
120 mm
Function Of Module:
emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE
Product Certifications:
TÃœV || cULus
Input Compatibility:
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Number Of Outputs:
7 on/off configurable pulsed output
Safety Level:
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay c
$461.64

Description

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, Proximity safety switch, PNP sensor, RFID safety switch or safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 6 safety inputs, 7 ON/OFF configurable pulsed outputs, 3 NO, 1 NC safety outputs, and 1 solid-state diagnostic output with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relay weighs 0,350kg. Its dimensions are 45mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC60947-5-1, IEC61508-1/2/3, ISO13849-1, IEC62061 functional safety standards, is certified by cULus, TÃœV, EAC, CCC and KC marking. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.