Description
1-conductor male connector; CAGE CLAMP; 2.5 mm²; Pin spacing 5 mm; 19-pole; DIN-35 rail/panel mounting; Snap-in mounting feet; 2,50 mm²; gray
View AllClose
Additional Information
actuation type: |
Operating tool |
approvals per: |
UL 1059 |
clamping spring material: |
Chrome nickel spring steel (CrNi) |
color: |
Gray |
conductor entry direction to mating direction: |
0 |
connection technology: |
CAGE CLAMP |
connector connection type: |
For conductor |
contact material: |
Electrolytic copper (ECu) |
contact plating: |
Tin-plated |
contact type pluggable connector: |
Male connector/plug |
country of origin sales organisation germany: |
DE |
depth: |
27.5 mm / 1.083 inch |
fine stranded conductor: |
0.08 2.5 mm / 28 12 AWG |
fine stranded conductor with insulated ferrule: |
0.25 1.5 mm |
fine stranded conductor with uninsulated ferrule: |
0.25 2.5 mm |
fire load: |
0.512 MJ |
flammability class per ul94: |
V0 |
height: |
18.8 mm / 0.74 inch |
height from the surface: |
14.3 mm / 0.563 inch |
housing sheet thickness: |
0.6 1.2 mm / 0.024 0.047 inch |
insulation material: |
Polyamide (PA66) |
legend ratings: |
(III / 2) Overvoltage category III / Pollution degree 2 |
limit temperature range: |
-60 +100 C |
locking of plug in connection: |
Without |
material group: |
I |
mismating protection: |
No |
mounting type: |
Snap-in foot || Panel mounting |
nominal voltage ii 2: |
630 V |
nominal voltage iii 3: |
320 V |
packaging type: |
Box |
pin spacing: |
5 mm / 0.197 inch |
pole no: |
19 |
rated current: |
0 |
rated current csa use group b: |
15 A |
rated current csa use group d: |
0.416666666666667 |
rated current ul 1977: |
15 A |
rated current ul use group b: |
15 A |
rated current ul use group d: |
0.416666666666667 |
rated surge voltage ii 2: |
4 kV |
rated surge voltage iii 2: |
4 kV |
rated surge voltage iii 3: |
4 kV |
rated voltage csa use group b: |
300 V |
rated voltage csa use group d: |
300 V |
rated voltage iii 2: |
320 V |
rated voltage ul 1977: |
600 V |
rated voltage ul use group b: |
300 V |
rated voltage ul use group d: |
300 V |
ratings per: |
IEC/EN 60664-1 |
safety information 1: |
The MCS MULTI CONNECTION SYSTEM includes connectors without breaking capacity in accordance with DIN EN 61984. When used as intended, these connectors must not be connected/disconnected when live or under load. The circuit design should ensure |
solid conductor: |
0.08 2.5 mm / 28 12 AWG |
strip length: |
8 9 mm / 0.31 0.35 inch |
weight: |
29.210 g |
width: |
98.2 mm / 3.866 inch |