null

WAGO 750-435

(No reviews yet) Write a Review
SKU:
750-435
Condition:
New
color:
Blue
conformity marking:
CE
connection technology inputs outputs:
8 x CAGE CLAMP
connection type 1:
Inputs/outputs
contact resistance max:
1000
country of origin sales organisation germany:
DE
current carrying capacity power jumper contacts:
0.0416666666666667
data width:
2-bit input: 1-bit status, 1-bit error (short circuit/wire break)
depth:
67.8 mm / 2.669 inch
depth from upper edge of din rail:
60.6 mm / 2.386 inch
diagnostics:
Short circuit, wire break
emc emission of interference:
Per EN 61000-6-3, marine applications
emc immunity to interference:
Per EN 61000-6-2, marine applications
ex guideline:
EN IEC 60079-0, -7, -11
exposure to pollutants:
Per IEC 60068-2-42 and IEC 60068-2-43
fine stranded conductor:
0.08 2.5 mm / 28 14 AWG
fire load:
0.874 MJ
height:
100 mm / 3.937 inch
housing material:
Polycarbonate: polyamide 6.6
input characteristic:
High-side switching
input data width internal max:
2 bits
input filter digital:
3 ms
input pulse length:
5 ms
input pulse separation:
3 ms
intrinsic safety ex i:
Yes
isolation:
300 VAC system/field
marking:
ATEX/IECEx: II 3 (1) G Ex ec [ia Ga] IIC T4 Gc: II (1) D [Ex ia Da] IIIC: I (M1) [Ex ia Ma] I
mounting position:
Horizontal (standing/lying): vertical
mounting type:
DIN-35 rail
note:
The digital input module must only be operated with a 24 VDC Ex i power supply!General information (e.g., installation regulations) on explosion protection is available in the WAGO I/O System 750 manuals!
number of digital inputs:
1
number of incoming power jumper contacts:
2
number of outgoing power jumper contacts:
2
open circuit voltage:
8.2 V
operating altitude:
0 2000 m
packaging type:
Box
permissible h2s contaminant concentration at a relative humidity 75:
10 ppm
permissible so2 contaminant concentration at a relative humidity 75:
25 ppm
pollution degree 5:
2 per IEC 61131-2
power consumption 5 v system supply:
2.5 mA
power consumption field supply module with no external load:
13 mA
power consumption pmax:
0.5 W
power loss pl:
0.37 W
protection against incorrect wiring:
Short circuit monitoring: > 6.4 mA || Wire break monitoring: < 0.2 mA
protection type:
IP20
reactances ex ia i:
Lo = 1 H: Co = 38 F
reactances ex ia iia:
Lo = 900 mH: Co = 36 F
reactances ex ia iib:
Lo = 560 mH: Co = 9 F
reactances ex ia iic:
Lo = 180 mH: Co = 1.4 F
reactances note:
Reactances without accounting for the concurrence of L and C
relative humidity without condensation:
0.95
safety relevant data circuit:
Uo = 12 V: Io = 16 mA: Po = 48 mW: Linear characteristic curve
sensor connection:
1 x (2-wire)
shock resistance:
15g per IEC 60068-2-27
short circuit current:
¤ 8.2 mA
signal current 0 namur:
1.2 mA
signal current 1 namur:
2.1 mA
signal type:
NAMUR
solid conductor:
0.08 2.5 mm / 28 14 AWG
strip length:
8 9 mm / 0.31 0.35 inch
supply voltage field:
24 VDC: (Ex i power supply: UO = max. 27.3 V): via power jumper contacts (power supply via blade contact: transmission via spring contact)
supply voltage sensor:
8.2 VDC: Short-circuit-protected, isolated channels
supply voltage system:
5 VDC: via data contacts
surrounding air temperature operation:
0 55 C
surrounding air temperature storage:
-40 85 C
switching hysteresis:
0.2 mA
total number of channels module:
1
vibration resistance:
4g per IEC 60068-2-6
weight:
46.000 g
width:
12 mm / 0.472 inch
$136.20