null

WAGO 787-2744

(No reviews yet) Write a Review
SKU:
787-2744
Condition:
New
conformity marking:
CE: EAC
connection technology:
Push-in CAGE CLAMP
connection technology 2:
Push-in CAGE CLAMP
connection technology 3:
Push-in CAGE CLAMP
connection type 1:
Input
connection type 2:
Output
connection type 3:
Signaling
control deviation:
¤ 1 %
country of origin sales organisation germany:
CN
default setting:
DC 24 V
depth from upper edge of din rail:
170 mm / 6.693 inch
derating:
-2 %/K (> 45 C)
discharge current:
¤ 3.5 mA
efficiency typ:
0.923
fine stranded conductor:
0.5 6 mm / 20 10 AWG
fine stranded conductor 2:
0.75 25 mm / 18 4 AWG
fine stranded conductor 3:
0.2 1.5 mm / v 14 AWG
fire load:
0.048 MJ
height:
130 mm / 5.118 inch
input current ii:
¤ 3 x 2.5 A (400 VAC)
input voltage range:
(2 / 3) x AC 325 575 V: DC 560 700 V
inrush current:
¤ 30 A (400 VAC)
internal fuse:
3 x T 6.3 A / 500 VAC
isolation voltage pri gnd:
DC 2.2 kV
isolation voltage pri sec:
DC 4.242 kV
isolation voltage sec gnd:
DC 0.7 kV
isolation voltage sec signal:
DC 0.7 kV
mains failure hold up time:
10 ms (3 x 400 VAC)
mounting type:
DIN-35 rail
mtbf:
> 1,300,000 h (per IEC 61709)
nominal input voltage ui nom:
(2 / 3) x AC 400 480 V
nominal mains frequency range:
47 63 Hz: 0 Hz
nominal output current io nom:
40 A (24 VDC)
nominal output power:
960 W
nominal output voltage uo nom:
DC 24 V (SELV)
open circuit proof:
Yes
operation status indicator:
Green LED (Uo) || Red LED (overload)
output voltage range:
DC 22 28 V (adjustable)
overload behavior:
Constant power (in overload range: 1.05 1.4 x Io nom): Shutdown and automatic restart in the event of a short circuit
overvoltage category:
II
packaging type:
Box
parallel operation:
Yes
phases:
2 || 3
pollution degree:
2
power factor:
0.7 (400 VAC)
power factor correction pfc:
Passive
power loss pl:
¤ 6.2 W (400 VAC: Nominal load): ¤ 64.3 W (400 VAC: Nominal load)
protection class:
I
protection type:
IP20 (per EN 60529)
recommended backup fusing:
3 x circuit breaker 10 A: Tripping characteristic: B or C
relative humidity:
10 95 % (no condensation permissible)
required backup fusing:
An external DC fuse is required for the DC input voltage.
residual ripple:
¤ 150 mV (Peak-to-peak)
resistance to reverse feed:
¤ DC 30 V
resistance to shock and vibration:
Shock: 15g (per EN 60068-2-27) || Vibration: 1g (per EN 60068-2-6)
series operation:
Max. 2 devices
short circuit protected:
Yes
signaling:
1 x LED DC OK (green) || 1 x Overload LED (red) || 1 x DC OK signal output (PhotoMOS as make contact: can be loaded with max. 31.2 V / 100 mA)
solid conductor:
0.5 6 mm / 20 10 AWG
solid conductor 2:
0.75 16 mm / 18 4 AWG
solid conductor 3:
0.2 1.5 mm / 24 14 AWG
standards specifications:
EN 61204-3 || EN 62368-1 || CURus 60950-1 || CURus 62368-1 || CULus 508 || CSA C22.2
strip length:
11 13 mm / 0.43 0.51 inch
strip length 2:
18 20 mm / 0.71 0.79 inch
strip length 3:
8 9 mm / 0.31 0.35 inch
surrounding air temperature operation:
-20 70 C
surrounding air temperature storage:
-40 85 C
transient suppression primary:
Varistor
wago connector:
WAGO 2606 Series
wago connector 2:
WAGO 2616 Series
wago connector 3:
picoMAX 3.5 (WAGO 2091 Series)
weight:
2630.000 g
width:
140 mm / 5.512 inch
  • Wago 787-2744
  • Wago 787-2744
  • Wago 787-2744
$475.00

Description

Primary switch mode power supplies

  • Economical power supply for standard applications
  • Natural convection cooling when horizontally mounted
  • Enclosed for use in control cabinets
  • Fast and tool-free termination via lever-actuated terminals with push-in connection technology
  • DC OK signal output
  • Parallel operation
  • Electrically isolated output voltage (SELV) per EN 60950-1/UL 60950-1; PELV per EN 60204
View AllClose