null

ABB abb-acs310

(No reviews yet) Write a Review
SKU:
abb-acs310

Description

Shop Online Here

A drive dedicated to optimize your variable torque applications, such as booster pumps and centrifugal fans. Designed with a powerful set of features that vary the drive’s performance in response to changes in pressure, flow or other external data. Helping you to save on operating costs, increase energy efficiency and reduce CO2 emissions.

Highlights

  • 0.37 to 11 kW/0.5 to 15 hp 200 V
  • 0.37 to 22 kW/0.5 to 30 hp 400 V
  • IP20 enclosure
  • Built-in pump and fan features such as multi-pump control, pipe clean and fill functions
  • Embedded Modbus EIA-485 interface

ABB ACS310 General Purpose Drives Catalog

ABB ACS310 User Manual

See all ACS310 Configurations Here - Online Purchase Available

1/2 thru 3 HP (1~230V In/ 3~230V Out)      1/2 thru 15 HP (3~230V In/3~230V Out)     1/2 thru 30 HP (3~460V In/3~460V Out)
Input ratings Input voltage range 200 - 240VAC; 380 - 480VAC
  Input voltage tolerance 10% / -10%
  Phase 1-phase 230 V, 3-phase 230/460 V
  Frequency 48 to 63Hz, maximum rate of change 17% / second
  Short circuit rating (UL 508c) 100,000 rms symmetrical amperes up to 600V when input cables protected by class T fuses or similar type fuse. 
65,000 rms symmetrical amperes up to 460V when input cables protected by ABB MS series Multiple Motor Protectors
Output ratings Horsepower 0.5 - 5 HP @ 230 VAC, 1PH 
0.25 - 3 HP @ 230 VAC, 3PH
0.5 - 15 HP @ 230 VAC, 3 PH
0.5 - 30 HP @ 460 VAC, 3 PH
  Overload capacity 110% overload capacity for up to 1 minute
  Frequency 0-500 Hz
  Voltage 0 to maximum input voltage
  Motor types Asynchronous AC induction motors
Protective features Overcurrent Over-current trip limit up to 325%
  DC overvoltage 130% of input voltage
  Overtemp Heatsink monitor (90°C / 203°F)
  Short circuit Phase-to-phase on drive output
  Undervoltage 65% of input voltage
  Loss of reference Trips on loss of speed command signal
  Motor overtemp Protected (I2t)
  Loss of keypad Drive will trip if under control panel control and communication is lost
  Motor stall Motor cannot achieve commanded speed due to excessive load
  Ground fault Ground fault detected in motor or motor cables
  Motor phase fault Loss at one of the motor phases
Environmental Temperature -10°C (14°F) to 40°C (104°F) - up to 50°C with 10% derate
  Cooling R0 frame convection, R1-R2 forced air
  Enclosure Standard IP20, Option kit UL Type 1 (IP21)
  Altitude 1,000 m (3,300 ft.).  Derate by 1% every 100 m (328 ft.) up to 2,000m (6,600 ft.)
  Humidity 0% to 95%, non-condensing
  Vibration 2…9 Hz, 3.0 mm (0.12 in)/9…200 Hz, 10 m/s2 (33 ft/s2)
Keypad display Display LCD Graphical Display
  Keys 8 key keypad (2-soft keys) with tactile response
  Functions Output status monitoring, digital and analog speed control, parameter setting and display, diagnostic and fault log display, motor run, local/remote toggle
  Remote mount  Remote mount option kit
  Trip Last three faults stored in fault history
Control specifications Switching frequency 4-16 kHz (4 kHz default)
  Accel/decel Two independently adjustable sets of speed ramps - 0-1800 Seconds 
  Speed control accuracy N/A -  V/Hz drive
  Skip frequencies Three configurable bands 0 to maximum frequency
  PC setup software DriveWindow Light, MFDT-01 FlashDrop
  Maximum output frequency 500 Hz
  Selectable operating modes 2-wire, 3-wire, Alternate, Motor Pot, Hand/Auto, Pump and fan control, Soft pump and fan control, PID Control, FlashDrop set, user sets
Analog inputs Two differential current or voltage 0-10VDC or 0/4 - 20maDC
  Resolution 11 bit + sign
Analog outputs One current outputs  0/4 - 20maDC
  Frequency range N/A
  Resolution N/A
Digital inputs Five digital inputs (4) Digital Inputs (1) pulse train input (DI5 can be used as DI or pulse train input)
  Input impedance PNP & NPN, 12-24VDC, (10V logic 0), Pulse train 0 to 16kHz, 2.4KΩ
  Filtering N/A
Digital outputs One relay & one digital output Relay output: Form C (NO + NC) Digital Output: Transistor output PNP
  Maximum switching voltage Relay Output: 250 V AC / 30 V DC, Digital Output: 30 V DC
  Maximum continuous current Relay ouput: 2 A rms, Digital output: 100 mA (Switching Current)
Safety Not Available N/A

How to Configure Multipump and Fan Control with Soft Start

View AllClose