ABB Baldor-Reliance CEWDM4400TS-4 100 HP 1785 RPM 405TSC TEFC Severe-Duty Washdown Motor
ABB Baldor-Reliance
| Catalog Number | CEWDM4402TS-4 |
| Output (HP) | 100 |
| Speed (RPM) | 3575 |
| Synchronous Speed (RPM) | 3600 |
| Number of Poles | 2 |
| Voltage (V @ 60 Hz) | 460 |
| Full Load Amps (A) | 116.0 |
| Phase | 3 |
| Frequency (Hz) | 60.00 |
| Frame | 405TSC |
| Frame Material | Iron |
| Enclosure | TEFC |
| Enclosure Modification | Severe Duty Features |
| Ingress Protection | Washdown / IP55 |
| NEMA Nominal Efficiency (%) | 95.0 |
| Service Factor | 1.15 |
| Insulation Class | F |
| Power Factor | 84 |
| Design Code | A |
| KVA Code | L |
| Motor Type | A4072M |
| Motor Letter Type | Three Phase |
| Mounting Arrangement | F1 |
| Base | Rigid |
| Shaft Diameter (in) | 2.125 |
| Overall Length (in) | 35.19 |
| Duty Rating | CONT |
| Ambient Temperature (C) | 40 |
| Inverter | Inverter Duty |
| Bearing Grease | Polyrex EM |
| Agency Approvals | NEMA Premium 4, CCSAUSEEV |
The CEWDM4402TS-4 is a large-frame 100 HP Baldor-Reliance severe-duty washdown motor in a 405TSC cast-iron frame with TEFC construction, Severe Duty Features, and Washdown / IP55 ingress protection. The epoxy/severe-duty finish and Polyrex EM grease target high-pressure washdown and corrosive process environments where full stainless is not required at this power level. Rated 95.0% nominal efficiency at 1.15 service factor, Class F insulation, Inverter Duty.
Spec note: Ship weight on page = 9,999 LB (Baldor placeholder) -> left blank. VERIFY actual weight.
Automation Distribution is an authorized distributor of ABB Baldor-Reliance motors serving PA, NJ, NY, DE, MD, DC, and VA. For lead time, quantity pricing, accessories, or application help on the CEWDM4402TS-4, request a quote or contact our team at 1-888-600-3080.