Baumer OM70-L0600.HH0500.EK 11216515
Baumer
The Baumer OM70-L0600.HH0500.EK 11216515 is a high-precision distance measuring device featuring a laser line basic version with a measuring distance of 100 to 600 mm and a measuring range of 500 mm. It offers a resolution between 3 to 24 µm and repeat accuracy from 1 to 9 µm. The device includes a webserver and Ethernet TCP/IP for adjustments, and it is equipped with multiple LED indicators for power, output, and Ethernet link status. It utilizes a pulsed red laser diode with a wavelength of 660 nm and is classified as Laser class 1. The response delay is minimal at 0.8 ms, and it operates at a high measuring frequency of 2000 Hz. The device supports both analog and digital outputs and includes safety features such as short circuit and reverse polarity protection. It is housed in a durable aluminum casing with glass optics, designed to withstand harsh environments with IP 67 protection and resistance to vibration and shock as per IEC standards. The compact design measures 26 mm in width, 74 mm in height, and 55 mm in depth, weighing 135 g. It operates effectively within a temperature range of -10 to +50 °C and is suitable for a variety of industrial applications.
- Scanning range Sd:
- 100 700 mm
- Scanning range far limit Sde:
- 110 700 mm
- Hysteresis typ.:
- 4 % Sde
- Repeat accuracy:
- 0.5 mm
- Synchronization:
- Yes
- Temperature drift:
- < 0,18 % Sde/K
- Response time ton (sync on):
- < 50 ms
- Release time toff (sync on):
- < 50 ms
- Sonic frequency:
- 240 kHz
- Adjustment:
- Potentiometer
- Alignment aid:
- Target indication flashing
- Output indicator:
- LED green
- Voltage supply range +Vs:
- 12 30 VDC
- Current consumption max. (no load):
- 30 mA
- Output circuit:
- PNP break function (NC)
- Output current:
- 200 mA
- Voltage drop Vd:
- <2 VDC
- Residual ripple:
- < 10 % Vs
- Short circuit protection:
- Yes
- Reverse polarity protection:
- Yes
- Design:
- Cylindrical threaded
- Housing material:
- Brass nickel plated
- Width / diameter:
- 18 mm
- Height / length:
- 89 mm
- Connection types:
- Cable, L=2 m
- Operating temperature:
- -10 +60 °C
- Protection class:
- IP 67
- Datasheet:
- View;