Baumer OZDM 16P3001 10140412
Baumer
The Baumer OZDM 16P3001 10140412 is a diffuse contrast sensor with a sensing distance of less than 250 mm and an optimum operating distance of 40 to 80 mm. It can detect remission differences greater than 8% on grey surfaces and offers repeat accuracy of less than 0.1 mm at laser focus. This sensor features a pulsed red laser diode light source, with a laser class of 1 and a wavelength of 650 nm. It has a fast response and release time of less than 0.05 ms. The sensor operates on a voltage supply range of 12 to 30 VDC, with a typical current consumption of 60 mA and a maximum of 65 mA. It includes short circuit and reverse polarity protection, and outputs through a PNP circuit with a dark operate function, capable of handling an output current of 200 mA. The sensor's robust design includes a die-cast zinc housing, glass optics, and is IP67 rated for protection against dust and water ingress. It operates within a temperature range of -10 to +50 °C and connects via a 3-pin, 2-meter cable.
- Type:
- Diffuse contrast sensor
- Sensing distance Tw:
- < 250 mm
- Optimum operating distance:
- 40 80 mm
- Detectable remission difference (on grey):
- > 8 %
- Repeat accuracy:
- < 0.1 mm at laser focus
- Output indicator:
- LED yellow
- Sensitivity adjustment:
- Potentiometer, 14 turn
- Distance to focus:
- 80 mmLight source=Pulsed red laser diode
- Laser class:
- 1
- Wave length:
- 650 nm
- Response time / release time:
- < 0.05 ms
- Voltage supply range +Vs:
- 12 30 VDC
- Current consumption max. (no load):
- 65 mA
- Current consumption typ.:
- 60 mA
- Voltage drop Vd:
- <2 VDC
- Output function:
- Dark operate
- Output circuit:
- PNP
- Output current:
- 200 mA
- Short circuit protection:
- Yes
- Reverse polarity protection:
- Yes
- Width / diameter:
- 15.4 mm
- Height / length:
- 50 mm
- Depth:
- 50 mm
- Design:
- Rectangular
- Housing material:
- Die-cast zinc
- Front (optics):
- Glass
- Connection types:
- Cable 3 pin, 2 m
- Protection class:
- IP 67
- Operating temperature:
- -10 +50 °C
- Datasheet:
- View
- QN-QUOTE-REQUEST:
- true