Leuze DMU330-3500.3/4CK-M12 Ultrasonic distance sensor
Leuze
$531.43
DMU330-3500.3/4CK-M12 Ultrasonic distance sensor
- Series:
- 330
- Contains:
- 2x M30 mounting nut
- Special version:
- Multiplex operation,Synchronous operation
- Ultrasonic frequency:
- 112 kHz
- Direction of beam:
- Front
- Opening angle:
- 7 °
- Measurement range:
- 250 ... 3,500 mm
- Resolution:
- 5 mm
- Accuracy:
- 1 %
- Reference value, accuracy:
- End value
- Repeatability:
- 0.5 %
- Reference value repeatability:
- End value
- Temperature drift:
- 8 %
- Protective circuit:
- Inductive protection,Polarity reversal protection,Short circuit protected
- Supply voltage UB:
- 12 ... 30 V, DC
- Residual ripple:
- 0 ... 5 %, From UB
- Open-circuit current:
- 0 ... 50 mA
- Switching hysteresis:
- 1 %
- Number of analog outputs:
- 1 Piece(s)
- Number of digital switching outputs:
- 1 Piece(s)
- Load resistance:
- 0 ... 500 ?
- Current:
- 4 ... 20 mA
- Type:
- Current
- Switching current, max.:
- 100 mA
- Switching element:
- Transistor, PNP
- Switching principle:
- NO (normally open)
- Number of inputs/outputs selectable:
- 1 Piece(s)
- Function:
- Preventing mutual interference
- Switching frequency:
- 2 Hz
- Response time:
- 250 ms
- Function:
- Signal IN,Signal OUT,Voltage supply
- Type of connection:
- Connector
- Thread size:
- M12
- Type:
- Male
- Material:
- Plastic
- No. of pins:
- 5 -pin
- Encoding:
- A-coded
- Design:
- Cylindrical
- Dimension (Ø x L):
- 30 mm x 98.8 mm
- Thread size:
- M30 x 1.5 mm
- Housing material:
- Plastic
- Plastic housing:
- Polybutylene (PBT)
- Sensing face material:
- Plastic, Epoxy resin, glass fiber reinforced
- Ultrasonic transducer material:
- Piezoceramics (contains lead zirconium titanate (PZT))
- Net weight:
- 140 g
- Housing color:
- Gray
- Type of display:
- LED
- Number of LEDs:
- 3 Piece(s)
- Operational controls:
- Control buttons
- Function of the operational control:
- NC contact / NO contact changeover,Resetting to factory settings,Setting for the switching outputs/characteristic output curve
- Ambient temperature, operation:
- -20 ... 70 °C
- Ambient temperature, storage:
- -20 ... 70 °C
- Degree of protection:
- IP 67
- Protection class:
- III
- Approvals:
- c UL US
- Standards applied:
- IEC 60947-5-2
- Customs tariff number:
- 85365019
- ECLASS 5.1.4:
- 27270804
- ECLASS 8.0:
- 27270804
- ECLASS 9.0:
- 27270804
- ECLASS 10.0:
- 27270804
- ECLASS 11.0:
- 27270804
- ECLASS 12.0:
- 27272806
- ECLASS 13.0:
- 27272806
- ECLASS 14.0:
- 27272806
- ECLASS 15.0:
- 27272806
- ETIM 5.0:
- EC001846
- ETIM 6.0:
- EC001846
- ETIM 7.0:
- EC001846
- ETIM 8.0:
- EC001846
- ETIM 9.0:
- EC001846
- ETIM 10.0:
- EC001846
- Datasheet:
- View
- Brochure:
- View
- Declaration of Conformity:
- View