Leuze RSL445-S Safety laser scanner
Leuze
            
            $7,725.91
        
         
            
                    RSL445-S Safety laser scanner
                    
                
                
            - Series:
 - RSL 400
 - Application:
 - Mobile danger zone guarding,Mobile side guarding,Stationary access guarding,Stationary danger zone guarding
 - Special version:
 - Measurement data output optimized for vehicle navigation
 - Functions:
 - Data output, configurable,Dynamic contactor monitoring (EDM), selectable,E-stop linkage,Four-field mode,Safe time delay, internal,Start/restart interlock (RES), selectable
 - Type:
 - 3, IEC/EN 61496
 - SIL:
 - 2, IEC 61508
 - SILCL:
 - 2, IEC/EN 62061
 - Performance Level (PL):
 - d, EN ISO 13849-1
 - PFHD:
 - 9E-08 per hour
 - Mission time:
 - 20 years, EN ISO 13849-1
 - Category:
 - 3, EN ISO 13849
 - Resolution (adjustable):
 - 30/40/50/60/70/150 mm
 - Minimum adjustable range:
 - 50 mm
 - Number of field pairs, switchable:
 - Up to 100
 - Number of quads, switchable:
 - 50
 - Number of protective functions:
 - 2 Piece(s)
 - Number of independent sensor configurations:
 - Up to 10
 - Diffuse reflection, min.:
 - 1.8 %
 - Operating range:
 - 0 ... 3 m
 - Number of field pairs:
 - Up to 100
 - Operating range:
 - 0 ... 20 m
 - Object size:
 - 150 mm x 150 mm
 - Diffuse reflection, min.:
 - 10 %
 - Light source:
 - Laser, Infrared
 - Wavelength:
 - 905 nm
 - Laser class:
 - 1, IEC/EN 60825-1:2014
 - Transmitted-signal shape:
 - Pulsed
 - Repetition frequency:
 - 90 kHz
 - Angular resolution:
 - 0.1 °
 - Scanning angle:
 - 270 °
 - Detection range:
 - 0 ... 50 m, Diffuse reflection > 90%
 - Diffuse reflection:
 - 90 %
 - Distance resolution, radial:
 - 1 mm
 - Distance resolution, lateral:
 - 0.1 °
 - Systematic measurement error Dmeas - Dreal:
 - min.: -20 mm,typ.: -10 mm,max.: 0 mm,, (Diffuse reflection: 1.8% retro-reflector,Measurement range: 0.2 25 m)
 - Measurement value noise:
 - 10 mm 1 ?,( Diffuse reflection: 1.8% 20%,Measurement range: 0 9 m, Diffuse reflection: 20% retro-reflector,Measurement range: 0 25 m)
 - Laser spot (H x W), 10 m:
 - 60 mm x 13 mm
 - Laser spot (H x W), 20 m:
 - 165 mm x 24 mm
 - Laser spot (H x W), 30 m:
 - 265 mm x 40 mm
 - Laser spot (H x W), 40 m:
 - 285 mm x 57 mm
 - Protective circuit:
 - Overvoltage protection
 - Supply voltage UB:
 - 24 V, DC, -30 ... 20 %
 - Current consumption (without load), max.:
 - 700 mA, (use power supply unit with 3 A)
 - Power consumption, max.:
 - 17 W, For 24 V, plus output load
 - Number of safety-related switching outputs (OSSDs):
 - 4 Piece(s)
 - Type:
 - Safety-related switching output OSSD
 - Switching voltage high, min.:
 - 20.8 V
 - Switching voltage low, max.:
 - 2 V
 - Voltage type:
 - DC
 - Response time:
 - 80 ms, ?
 - Type:
 - Bluetooth, Ethernet, USB
 - Function:
 - Configuration/parametization,TCP/IP
 - Connection:
 - M12 connector, 4-pin, D-coded
 - Frequency band:
 - 2,400 ... 2,483.5 MHz
 - Radiated transmitting power:
 - Max. 4.5 dBm (2.82 mW), class 2
 - Connection:
 - USB 2.0 mini-B, socket
 - Transmission speed, max.:
 - 12 Mbit/s
 - Cable length:
 - ? 5m,Longer cable lengths are possible using active cables.
 - Dimension (W x H x L):
 - 140 mm x 149 mm x 140 mm
 - Housing material:
 - Metal,Plastic
 - Metal housing:
 - Diecast zinc
 - Lens cover material:
 - Plastic/PC
 - Net weight:
 - 2,000 g
 - Housing color:
 - Yellow, RAL 1021
 - Type of fastening:
 - Mounting plate,Through-hole mounting,Via optional mounting device
 - Type of display:
 - Alphanumerical display,LED indicator
 - Number of LEDs:
 - 6 Piece(s)
 - Type of configuration:
 - Software Sensor Studio
 - Operational controls:
 - Software Sensor Studio
 - Ambient temperature, operation:
 - 0 ... 50 °C
 - Ambient temperature, storage:
 - -20 ... 60 °C
 - Relative humidity (non-condensing):
 - 15 ... 95 %
 - Degree of protection:
 - IP 65
 - Protection class:
 - III, EN 61140
 - Approvals:
 - TÜV Süd
 - Test procedure for EMC in accordance with standard:
 - DIN 40839-1/3,EN 61496-1
 - Test procedure for oscillation in accordance with standard:
 - EN 60068-2-6
 - Test procedure for continuous shock in accordance with standard:
 - IEC 60068-2-29
 - US patents:
 - US 7,656,917 B,US 7,696,468 B,US 8,520,221 B,US 10,304,307B
 - Customs tariff number:
 - 85365019
 - ECLASS 5.1.4:
 - 27279290
 - ECLASS 8.0:
 - 27279290
 - ECLASS 9.0:
 - 27272705
 - ECLASS 10.0:
 - 27272791
 - ECLASS 11.0:
 - 27272791
 - ECLASS 12.0:
 - 27272791
 - ECLASS 13.0:
 - 27272791
 - ECLASS 14.0:
 - 27272791
 - ECLASS 15.0:
 - 27272791
 - ETIM 5.0:
 - EC002550
 - ETIM 6.0:
 - EC002550
 - ETIM 7.0:
 - EC002550
 - ETIM 8.0:
 - EC003015
 - ETIM 9.0:
 - EC003015
 - ETIM 10.0:
 - EC003015
 - Datasheet:
 - View
 - Brochure:
 - View
 - Declaration of Conformity:
 - View