Lutze 113322 superflex plus n(c)pur

(No reviews yet) Write a Review
SKU:
113322
Condition:
New
QN-QUOTE-REQUEST:
true
$14.28

Description

Technical Data

Construction

Description
SUPERFLEX?? PLUS N (C) PUR 600V
Number of conductors/cross-section
(18G1.5)
Jacket material
PUR
Jacket color
grey RAL 7001
Outer ??
17,2 mm
Outer ??
0,677 inch
Weight
48,7 kg/100 m
Weight
308 Lbs/Mft
Cu-Index
32,4 kg/100 m
Cu-Index
217 Lbs/Mft

Element 1

Element construction
(18G1.5)
Conductor
CU-wire bare
Conductor category
  • IEC 60228, Class 6
  • Superfinely stranded DIN VDE 0295
  • class 6
Conductor marking
  • black
  • with white number print
  • green/yellow
Conductor marking standard
DIN EN 50334
Conductor insulation
Special TPE

overall construction

Overall stranding
  • conductors layered construction
  • layer pitch optimised
  • conductors twisted without mechanical stress
Overall wrapping
Fleece taping
Inner jacket
TPE
Overall shield
  • Braid shield
  • Tinned copper wires
  • optical cover approx. 85%
Jacket characteristics
  • Flame-retardant
  • self-extinguishing
  • Oil resistant
  • grease-resistant
  • petrol-resistant (alcohol-free)
  • kerosene-resistant
  • Silicone-free
  • Halogen free

Technical data

Rated voltage U0/U
300/500 V
Rated voltage UL
600 V
Test voltage type
AC6000V
Temperature according to UL
80 ???C
Temperature range moving
-25 ???C ?? +80 ???C
Temperature range fixed
-40 ???C ?? +80 ???C
Minimum bending radius moving
10??D
Minimum bending radius fixed
6??D

Element 1

Element construction
(18G1.5)
Insulation resistance at 20 ???C
1000 M???km
Operating capacitance wire-wire
75 pF/m
Operating capacitance wire-shield
108 pF/m

Approvals/Standards

Approvals
cURus
UL style
AWM 20234
Conformity
  • CE
  • RoHS
  • REACH
Burning behavior according to
  • IEC 60332-1
  • DIN EN 60332-1-2
  • VDE 0482 322-1-2
  • UL 1581 Part VW-1 Flame Test
  • UL FT1
Halogen free according to
  • DIN EN 60754-1
  • IEC 60754-1
UV-resistant according to
DIN EN ISO 4892-2-A

General

Note
CE These products are in conformity with the EU Low Voltage Directive 2014/35/EU

Machine and device construction, transport and conveyor technology, HVAC technology In areas with high concentrations of people or material assets, where corrosive gases need to be avoided in the event of fire As a monitoring, measurement and control cable for industrial applications Especially for harsh environments For installation in energy chains with constant linear movement Anywhere where electrical interference fields can influence the signal transmission

View AllClose