Alternative connection for second muting signal,Configuration by means of wiring,Contactor monitoring (EDM), selectable,Muting-timeout extension,Muting enable function,Sequence controlled 2-sensor muting,Start/restart interlock (RES),Timing controlle
Integrated laser alignment aid:
No
Integrated muting indicator:
No
Integrated status indicator:
No
Type:
2, IEC/EN 61496
SIL:
1, IEC 61508
SILCL:
1, IEC/EN 62061
Performance Level (PL):
c, EN ISO 13849-1
MTTFd:
204 years, EN ISO 13849-1
PFHD:
1.2E-08 per hour
Mission time:
20 years, EN ISO 13849-1
Category:
3, EN ISO 13849
Operating range:
0.5 ... 6 m
Operating range in connection with MLD-XM03:
0.5 ... 8 m
Number of beams:
3 Piece(s)
Beam spacing:
400 mm
Light source:
LED, Infrared
Wavelength:
850 nm
Transmitted-signal shape:
Pulsed
LED group:
1
Selection of operating mode:
Connection 1, pin 2: +24 V for operating mode 1, 2, 4,Connection 1, pin 2: 0 V for operating mode 3, 5, 6,Connection 1, pin 7: +24 V for operating mode 3, 5, 6,Connection 1, pin 7: 0 V for operating mode 1, 2, 4
Protective circuit:
Overvoltage protection,Short circuit protected
Supply voltage UB:
24 V, DC, -20 ... 20 %
Current consumption, max.:
150 mA, Without external load
Fuse:
External with max. 3 A
Number of digital switching inputs:
4 Piece(s)
Type:
Digital switching input
Switching current, max.:
5 mA
Number of safety-related switching outputs (OSSDs):