Collision protection of cranes / gantry cranes,Fill-level monitoring,Length measurement in material cutting,Positioning of skillet systems and side-tracking skates
Type of scanning system:
Against object
Light source:
Laser, Red
Laser class:
2, IEC/EN 60825-1:2014
Light spot size [at sensor distance]:
6 mm [10,000 mm]
Measurement range (6 90 % diffuse reflection):
200 ... 30,000 mm
Measurement range (90 % diffuse reflection):
200 ... 65,000 mm
Resolution:
0.1 mm display resolution, adjustable
Resolution:
1.0 mm
Accuracy:
2 mm, (+/-) at 90% diffuse reflection / 5 mm (+/-) at 6% diffuse reflection